DALI-2 D4i high-bay PIR occupancy sensor in Zhaga Book 18 format, for high-bay luminaires with a mounting height up to 15 m.
Operating Voltage Range12-36 VDC
Dimming (Output) Interface:DALI/DALI-2
DALI Bus Current Consumption:10.0000 mA
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:15.0000 m
Product overview
Overview. The Hytronik HIR15/D2 is a high-bay PIR occupancy sensor, a DALI-2 D4i Type B input device designed for industrial and outdoor applications with a maximum mounting height of 15 m.
Main characteristics. 360° PIR detection with a 24x15 detection diameter, adjustable sensitivity at 10%, 50%, 75% and 100%, and a removable shielding cap allowing the detection area to be adjusted. The sensor supports the DALI-2 occupancy (part 303) and daylight (part 304) features.
Interfaces and connectivity. DALI/DALI-2 dimming output interface, commissioning by DALI Master/Application Controller, and Zhaga Book 18 connector for tool-free integration into the luminaire. DALI bus current consumption of 10.0000 mA.
Power and environment. Operating voltage range of 12 to 36 VDC, IP65 rating, ambient temperature from -20 °C to 50 °C, storage temperature from -40 °C to 70 °C, humidity from 10% to 90%.
Typical uses. Lighting of large spaces such as warehouses and logistics facilities, as well as outdoor and street lighting.
Integration. Product dimensions of 50.4 mm x 50.4 mm x 43.8 mm for a weight of 45.0000 g. The product is compatible with the HA18SKT receptacle (Zhaga Book 18). Available on quotation from Atlas Electronics.
DALI-2 D4i high-bay PIR occupancy sensor in Zhaga Book 18 format, for high-bay luminaires with a mounting height up to 15 m.
Operating Voltage Range12-36 VDC
Dimming (Output) Interface:DALI/DALI-2
DALI Bus Current Consumption:10.0000 mA
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
2. Datasheet extract (recorded values)
Parameter
Value
Ambient temperature max.:
50 °C
Ambient temperature min.:
-20 °C
Commissioning Methods:
DALI Master/Application Controller
Connector Type
Zhaga book 18
DALI-2 D4i type:
Typ B
DALI-2 feature
Occupancy (part 303) Daylight (part 304)
DALI Bus Current Consumption:
10.0000 mA
Daylight Harvest:
No
Detection Angle
360°
Detection Methods:
Passive Infrared (PIR)
Detection range (Diameter):
24x15
Dimming (Output) Interface:
DALI/DALI-2
Features
D4i, Daylight Harvest
Human Centric Lightning (HCL):
No
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Built-in, Zhaga
IP Rate
IP65
Lens type
Standard Low-bay
Maximum Mounting Height:
15.0000 m
Mounting height
Mid & High-bay
Operating Voltage Range
12-36 VDC
Product Height
43.8000 mm
Product Length
50.4000 mm
Product Status:
Active / New
Product Weight
45.0000 g
Product Width
50.4000 mm
Sensitivity
10% /50% / 75% / 100%
Standardized
Zhaga Book 18 interface with IP65 for reliable integration
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
No
Voltage Type:
DC
Zhaga:
Yes
Applications and use cases
Architectures in which HIR15/D2 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for HIR15/D2 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details