Plug-and-play passive infrared (PIR) sensor head for luminaires, compatible with Hytronik Bluetooth control bases for occupancy detection and daylight-based lighting control.
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:12.0000 m
Mounting heightMid & High-bay
Mounting Hole22.0000 mm
Ambient temperature max.:50 °C
Product overview
Hytronik HIR63/R is a plug-and-play passive infrared (PIR) occupancy sensor head designed for reinforced mid-bay applications, with a typical mounting height of 6 m. — Overview — The HIR63/R is a 360° detection head with a detection range diameter of 20 x 12, fitted with a reinforced low-bay lens. Its maximum mounting height is 12.0 m. Main characteristics — Product dimensions of 36.0 mm x 36.0 mm x 43.4 mm for a weight of 23.0 g. Warm-up time of 20 s. The sensor does not feature daylight harvesting or tri-level corridor function, although these functions can be extended depending on the control base used. Interfaces and connectivity — RJ12 connector and M 22 x 1.5 mm conduit thread, 22.0 mm mounting hole. It is a built-in, plug-and-play sensor head that allows fast replacement and easy upgrading of sensing functions. Compatible with Bluetooth control bases and drivers. Power and environment — DC voltage type. Operating temperature from -20 °C to 50 °C, storage temperature from -40 °C to 70 °C, humidity from 10 % to 90 %. IP20 rating, facial part IP 65. Typical uses — Designed for upgrading metal luminaires to wireless control, with dimming and presence-based lighting control in warehouse and logistics, and production and industrial environments. Integration — Combines with the Bluetooth control bases HCD038/BT, HC038V/BT and HC438V/BT to add smart sensing capability to a luminaire.
Plug-and-play passive infrared (PIR) sensor head for luminaires, compatible with Hytronik Bluetooth control bases for occupancy detection and daylight-based lighting control.
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:12.0000 m
Mounting heightMid & High-bay
Mounting Hole22.0000 mm
2. Datasheet extract (recorded values)
Parameter
Value
Ambient temperature max.:
50 °C
Ambient temperature min.:
-20 °C
Compatible
Compatible with Bluetooth control bases and drivers
Conduit thread
M 22x1.5mm
Connector Type
RJ12
Daylight Harvest:
No
Daylight Sensor Option:
Photocell
Detection Angle
360°
Detection Methods:
Passive Infrared (PIR)
Detection range (Diameter):
20x12
Features
Daylight Harvest, Tri-level (Corridor Function)
Flexible
Easy upgrade or extension of sensing functions
Human Centric Lightning (HCL):
No
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Built-in, Plug & Play Sensor Heads
IP Rate
IP20
IP Rate (facial part):
IP 65
Lens type
Reinforced Low-bay
Maximum Mounting Height:
12.0000 m
Mounting height
Mid & High-bay
Mounting Hole
22.0000 mm
Plug-and-play
Enabling fast installation and replacement
Product Height
43.4000 mm
Product Length
36.0000 mm
Product Status:
Active / Make to Stock
Product Weight
23.0000 g
Product Width
36.0000 mm
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
No
Voltage Type:
DC
Warming-up:
20 s
Zhaga:
No
Applications and use cases
Architectures in which HIR63/R can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for HIR63/R and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details