The Hytronik HMW28/AA is an autonomous HF motion sensor with on/off relay control, designed for lighting control in corridors, offices and classrooms.
Operating Voltage Range220-240 VAC 50/60 Hz
Dimming (Output) Interface:Relay On/Off
HF operating frequency (Ghz):5.8Ghz+/-75MHz
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:3.0000 m
Product overview
Overview. The Hytronik HMW28/AA is an autonomous HF motion sensor with on/off relay control, using 5.8 GHz microwave detection. It is designed in a metal surface mount box for wall or surface mounting.
Main characteristics. The sensor provides microwave (MW) detection over 360° and an adjustable angle extending up to 70 degrees, with 360-degree rotation. It handles on/off occupancy control for up to 800 W. It suits a maximum mounting height of 3.0 m in low-bay mounting with a standard lens, and its detection range is given as a diameter of 2.5 × 22.
Commissioning and interfaces. Commissioning is done with an IR remote controller, using one-key setup. The control output is a relay on/off type, with a standard 2-cable connector. The sensor is standalone, without tri-level corridor function or dimming output.
Power and environment. It operates on 220-240 VAC 50/60 Hz. Its ambient temperature range is -20 °C to 50 °C, its storage temperature range is -40 °C to 70 °C and its humidity range is 10 % to 90 %. Its IP rating is IP20, for indoor use.
Typical uses. The HMW28/AA suits lighting control in corridors and hallways, as well as in classrooms and offices, as indicated by the manufacturer. It is compatible with the HRC-12 sensor remote controller for full functionality.
Dimensions. The product measures 94 × 94 × 115 mm and weighs 336 g.
The Hytronik HMW28/AA is an autonomous HF motion sensor with on/off relay control, designed for lighting control in corridors, offices and classrooms.
Operating Voltage Range220-240 VAC 50/60 Hz
Dimming (Output) Interface:Relay On/Off
HF operating frequency (Ghz):5.8Ghz+/-75MHz
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
2. Datasheet extract (recorded values)
Parameter
Value
Adjustable
Max.,70 degree angle + 360 degree rotatable for detection
Ambient temperature max.:
50 °C
Ambient temperature min.:
-20 °C
Autonomous
On/Off occupancy control for up to 800W
Commissioning Methods:
IR Remote Controller
Connector Type
Standard 2 cables
Daylight Sensor Option:
Photodiode/Photocell
Detection Angle
360°
Detection Methods:
Microwave (MW)
Detection range (Diameter):
2.5×22
Dimming (Output) Interface:
Relay On/Off
HF operating frequency (Ghz):
5.8Ghz+/-75MHz
Human Centric Lightning (HCL):
No
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Stand-alone
IP Rate
IP20
Lens type
Standard Low-bay
Maximum Mounting Height:
3.0000 m
Mounting height
Low-bay
Mounting Hole
4.2000 mm
Operating Voltage Range
220-240 VAC 50/60 Hz
Product Height
115.0000 mm
Product Length
94.0000 mm
Product Weight
336.0000 g
Product Width
94.0000 mm
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
No
User-Friendly
With one-key commissioning via IR controller
Voltage Type:
AC
Zhaga:
No
Applications and use cases
Architectures in which HMW28/AA can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Badges are lent and lost, and attendance is noted by hand. Face or fingerprint terminals, access controllers, door stations and locks control who enters and record working time
To check
Number of users and doors
Data protection rules for biometric data
Link with the payroll or HR software
Associated system blocks
TerminalsControllers and locksDoor stations
Need a complete solution?
Send a request for HMW28/AA and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details