M-7084-G – 4/8-channel counter, frequency and encoder input module RS-485

4/8-channel counter, frequency and encoder input module RS-485

Modular DIN-Rail Remote I/O Modules

  • -25 ~ +75 °C
  • +10 ~ +30 VDC
  • 1.32 W Max.
  • Freq+ CAx+ Freq - CAx-
Manufacturer part number
M-7084-G
Manufacturer
ICP DAS
Operating Temperature
-25 ~ +75 °C
Frequency Range
Frequency Error (typical)

The M-7084-G is a 4 or 8 channel counter, frequency and encoder input module for DIN rail, with an RS-485 port and Modbus RTU and DCON protocols.

Product overview

Overview. The ICP DAS M-7084-G is a remote counter, frequency and encoder input module for DIN rail mounting. It provides eight counter or frequency channels, or four encoder channels, with 32-bit counters. Each channel can be configured individually in Up Counter, Frequency Input, Up/Down Counter, Dir/Pulse and AB Phase modes.

Main characteristics. Programmable low pass filter from 1 to 32767 μs, virtual battery backup to preserve counter values, preset values for counter input, and programmable watchdog timer for the module and communication. Inputs accept +10 to +30 VDC, with an ON voltage level of +3.5 to +30 VDC and an OFF voltage level of +1 VDC maximum. Maximum frequency is 200 kHz, with a frequency accuracy of ±0.025 % of input frequency between 1 Hz and 200 kHz. Sink (NPN/PNP) type.

Interfaces and connectivity. One RS-485 port with Modbus RTU and DCON protocols, baud rates from 1200 to 115200 bps, data formats (N, 8, 1), (N, 8, 2), (E, 8, 1) and (O, 8, 1). A status indicator shows power and communication.

Power and environment. Maximum consumption of 1.32 W, 3000 VDC intra-module isolation, reverse polarity protection. ESD ±4 kV contact, EFT ±4 kV on power line and surge ±3 kV on power line according to IEC 61000-4-2, IEC 61000-4-4 and IEC 61000-4-5. Operating temperature -25 to +75 °C, storage -30 to +80 °C, humidity 10 to 90 % RH non-condensing. Dimensions 72 x 123 x 35 mm.

Typical uses. Pulse counting, frequency measurement and incremental encoder reading (CW/CCW, Dir/Pulse, AB Phase) from a PLC or supervisory system connected on the RS-485 bus.

Integration. DIN rail mounting. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • A/B Phase: A0+ CAx+ A0 - CAx- B0+ CBx+ B0 - CBx-
  • Battery Backup: Yes
  • Baud rate: 1200 ~ 115200 bps
  • Channels: 4-channel Up/Down Counter (CW/CCW)
  • Consumption: 1.32 W Max.
  • Counter/Encoder Bits: 32-bit

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25 ~ +75 °C — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote