The ICP DAS PCC-1416 is a 4.3-inch touch HMI that acts as an electronic CAM controller, replacing mechanical cams to drive axis movements from an absolute encoder.
Operating Temperature-20 ~ +50° C
Input Range+ 12 ~ 48 VDC
Consumption2.5 W
Load Current100 mA (per channel)
Storage Temperature-30 ~ +80 ° C
Channels1x Start Input 3x Bank Input
Product overview
ICP DAS PCC-1416. The PCC-1416 is a 4.3-inch touch HMI with an integrated electronic CAM controller. It uses digital signal processing to replace the traditional mechanical CAM system, eliminating mechanical noise and component wear while enabling higher speed and more precise operation.
Main characteristics. TFT LCD display at 480 x 272 resolution (65535 colours), brightness of 400 cd/m2, backlight life of 20,000 hours, touch screen and virtual numeric keypad. The module has 1 axis, 1 Start input and 3 Bank inputs, with 8 banks, 16 outputs and 32 area settings. It supports binary and Gray code and absolute encoders, with a response time of 150 μs (max.) and a 0 to 9 rotary switch.
Interfaces and connectivity. One USB 3.1 port is provided for firmware updates only. The module includes a reset button and a buzzer, and the output is Sink (NPN) with a load current of 100 mA per channel.
Power and environment. Input range of 12 to 48 VDC, consumption of 2.5 W. IP65 front panel, operating temperature of -20 to +50 °C, storage temperature of -30 to +80 °C, humidity of 10 to 90 % RH non-condensing. DIN-rail or wall mounting, panel cut-out of 120 ± 1 x 92 ± 1 mm.
Typical uses. Motion and positioning control on machine tools and automated lines where a mechanical cam must be replaced, with parameter storage and password protection.
The ICP DAS PCC-1416 is a 4.3-inch touch HMI that acts as an electronic CAM controller, replacing mechanical cams to drive axis movements from an absolute encoder.
Points to check before using PCC-1416 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20 ~ +50° C — check it against the installation environment.
Power and communication
Consumption
2.5 W
Load Current
100 mA (per channel)
Load voltage
+ 30VDC (Max.)
OFF Voltage Level
+ 10 ~ 24 VDC
ON Voltage Level
+ 3 VDC (Max.)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20 ~ +50° C — check it against the installation environment.
Applications and use cases
Architectures in which PCC-1416 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Every intervention on a remote machine means a trip on site. A 4G or 5G router with VPN gives the maintenance team secure access to the PLC and the operator panel from the office
To check
VPN type and how access rights are granted and removed
Mobile coverage at the machine site
Separation between the machine network and the customer network
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details