RPAC-2658M – Win-GRAF Linux programmable automation controller, quad-core

Win-GRAF Linux programmable automation controller, quad-core

Programmable Logic Controllers (PLC)

  • Ethernet
  • Arm architecture
  • Embedded Linux
Manufacturer part number
RPAC-2658M
Manufacturer
ICP DAS
File Access & Data Log
Supports fi le Read/Write.

ICP DAS Win-GRAF programmable automation controller (PAC) running Linux, with a quad-core Cortex-A9 processor and three Ethernet ports, for industrial automation and remote I/O control.

Product overview

ICP DAS RPAC-2658M. Win-GRAF programmable automation controller (PAC) running Linux, compliant with IEC 61131-3 through its embedded Win-GRAF SoftLogic.

Main characteristics. 1.0 GHz quad-core Cortex-A9 processor, 1 GB DDR3 RAM and 8 GB eMMC Flash, Linux kernel 4.1.15, built-in Xenomai real-time core architecture and 64-bit hardware serial number for software protection.

Interfaces and connectivity. Three 10/100/1000M Ethernet ports and four serial ports (RS-232/485/422). Modbus RTU/ASCII master and slave on up to 32 communication ports, Modbus TCP/IP master for up to 128 IP devices and slave with up to 64 connections via the two ports LAN1 and LAN2, and user-defined protocols on up to 32 ports.

Remote I/O and integration. Supports DCON remote I/O of the I-7000, M-7000 and I-87K series, Modbus RTU I/O of the M-7000, tM and LC series, and Modbus TCP I/O of the ET-7000, I-8KE4/8-MTCP, tPET and tET series.

Redundancy and system functions. Two RPAC-2658M units can form a redundant system, with a redundancy switchover time of 0.2 seconds. Online program modification (On-line Change), retain variables using up to 128K bytes of non-volatile memory, data binding between Win-GRAF devices and file read/write for data logging.

Typical uses. Process control and data collection on installations equipped with DCON or Modbus I/O, with redundancy where continuous operation is required.

See all specifications

Highlights

  • Data Binding: Supported. Enables data exchange between Win-GRAF Runtime devices.
  • DCON Remote I/O: Supports I-7000 series, M-7000 series, and I-87K expansion units.
  • File Access & Data Log: Supports fi le Read/Write.
  • Modbus RTU/ASCII Master: Supported. Up to 32 communication ports.
  • Modbus RTU I/O: Supports M-7000 series, tM series, and LC series I/O modules.
  • Modbus RTU Slave: Supported. Up to 32 communication ports.

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote