DRY-TYPE-TRANSFORMER-TEMPERATURE-CONTROLLER-BWDK-S3206
Dry-type transformer temperature controller, 3 windings

- Temperature range
- -30.0℃~240.0℃
- Working frequency rate
- 50Hz OR 60Hz(±2Hz)
- Ambient Humidity
- <95% (25ºC)
- Ambient temperature
- -20ºC~+55ºC
Dry-type transformer temperature controller, 3 windings
INNO BWDK-S3206 temperature controller for dry-type transformers: it monitors up to three windings and automatically controls the cooling fan as well as over-temperature alarm and trip outputs.
Overview. The INNO BWDK-S3206 is a microcontroller-based intelligent controller designed for the thermal monitoring of dry-type transformers. It uses platinum thermistor sensors embedded in the windings to measure and display the maximum temperature, over a range of -30.0 ℃ to 240.0 ℃ with a resolution of 0.1 ℃.
Main functions. It monitors up to three dry-type transformer windings, drives the built-in cooling with automatic fan control and fan exerciser function, and handles alarm and trip through relay outputs. It also includes automatic fault detection, historical record, temperature range revision, self-inspection and switch input judging.
Interfaces and communication. The control output is rated 5 A/250 VAC and 5 A/30 VDC (resistive load), and the fan output has a total capacity of 5 A/250 VAC. Model BWDK-S3206F provides RS485 or RS232 serial communication, and model BWDK-S3206E a 4-20 mA output for integration with SCADA systems. Variants BWDK-S3206G and BWDK-S3206I add, respectively, an ambient temperature sensor and a silicon steel sheet temperature sensor.
Power and environment. Working voltage AC 220 V (+10%, -15%), working frequency 50 Hz or 60 Hz (±2 Hz), power dissipation at most 8 W. Measurement accuracy ±1 % FS (thermostat level 0.5, sensor class B). Ambient temperature -20 ºC to +55 ºC, ambient humidity below 95 % (25 ºC).
Standards. Produced to JB/T7631-2005, the electronic temperature controller standard for transformers, under an ISO9001:2008 quality management system. Tested to IEC61000-4:1995 and GB/T17626-2008 for electromagnetic compatibility.
Typical uses. Suited to monitoring dry-type distribution transformers, with data transmitted to a PLC or supervision system through the serial or analogue outputs.
Available from Atlas Electronics on quotation.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DRY-TYPE-TRANSFORMER-TEMPERATURE-CONTROLLER-BWDK-S3206, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Adoption of accreditation standards | ISO9001:2008 International Quality Management System Certification |
| Ambient Humidity | <95% (25ºC) |
| Ambient temperature | -20ºC~+55ºC |
| BWDK-S3206D | Monitor up to three dry-type transformer windings; Display maximum temperature; Built-in fan control, fan exerciser; Alarming function and relay output control; Trip function and relay output control; Automatic fault detection function; Historical record function; Range in temperature revise; Self-inspection; Switch input judging function. |
| BWDK-S3206E | 4-20mA output for integration with SCADA systems |
| BWDK-S3206F | RS485 or RS232 serial communication function. |
| BWDK-S3206G | An additional sensor is added to measure the ambient temperature |
| BWDK-S3206I | An additional sensor is added to measure the temperature of silicon steel sheet |
| Control output capacity | 5A/250VAC;5A/30VDC(resistivity) |
| Fan output total capacity | 5A/250VAC |
| Measurement Accuracy | ±1%FS(Thermostat level 0.5,Sensor class B) |
| Power dissipation | ≤8W |
| Production standards | JB/T7631-2005 Electronic temperature controller for Transformers”Industry standards |
| Resolution ratio | 0.1ºC |
| Temperature range | -30.0℃~240.0℃ |
| Working frequency rate | 50Hz OR 60Hz(±2Hz) |
| Working voltage | AC 220V (+10%,-15%) |
No specification matches.
Last verification : 2026-11-02
Answers to the questions that the recorded characteristics of DRY-TYPE-TRANSFORMER-TEMPERATURE-CONTROLLER-BWDK-S3206 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "BWDK-S3206F": RS485 or RS232 serial communication function..
Yes — recorded under "BWDK-S3206F": RS485 or RS232 serial communication function..
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Dry-type transformer temperature controller, 3 windings

Dry type transformer temperature control box

Transformer Monitor-Temperature controller for Electric power transformer BWDK

Dry type transformer temperature controller

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DRY-TYPE-TRANSFORMER-TEMPERATURE-CONTROLLER-BWDK-S3206 |
| Manufacturer | INNO |
Temperature Controllers
Electronic temperature controller with analog or digital setting · Ref. : E5L
Price on request
Temperature Controllers
Transformer winding temperature controller with 4-20 mA output · Ref. : BWR-04J
Price on request
Temperature Controllers
High-Performance Cascade Temperature Controller with Dual Inputs · Ref. : AI-8X9
Price on request
Temperature Controllers
Transformer oil level temperature controller with digital thermometer · Ref. : D804AITH
Price on request