TRANSIT-PT100 – Temperature controller for rail transit dry-type transformers PT100

Temperature controller for rail transit dry-type transformers PT100

Temperature Controllers

  • -30.0 ºC~240 ºC
  • -19.9 ºC~+19.9 ºC
  • 3-7 routes;
  • ≤ ± 0.5 ºC
Manufacturer part number
TRANSIT-PT100
Manufacturer
INNO
Measuring Range
-30.0 ºC~240 ºC
External dimensions
400*320*100mm(Customizable)

INNO temperature controller for rail transit dry-type transformers, with PT100 measurement on three windings and one iron core and automatic or manual control of the cooling fan.

Product overview

Overview. The TRANSIT-PT100 from INNO is a temperature controller for dry-type transformers designed for rail transit, including subways and locomotives. It measures and regulates the temperature of the windings and the core.

Main characteristics. The product provides temperature measurement on three windings and one iron core, with 3 to 7 measurement channels. The measuring range is -30.0 ºC to 240 ºC with a resolution of 0.1 ºC, a measurement accuracy of ±1% FS and a control error of less than or equal to ± 0.5 ºC. It includes digital compensation of the displayed values for each channel, an LCD display with LED backlight, and a clock function. Automatic or manual start and stop of the cooling fan is built in.

Outputs and contacts. The control contacts have a capacity of 5 A at DC 220 V, DC 110 V or AC 250 V, customizable. The fan contact has a capacity of 5 A at AC 250 V. Four independent 4-20 mA analog current outputs are available as an option.

Power supply and environment. The working power supply is AC 220 V, DC 110 V or DC 220 V (-15% to +10%), and the working frequency is 50 Hz or 60 Hz (± 2 Hz) for AC supply. The enclosure has an IP54 protection level. It operates between -20 ºC and +55 ºC with humidity below 90%. External dimensions are 400 × 320 × 100 mm, with embedded or wall-mounted installation. The standard sensing cable length is 4 meters, customizable.

Uses and integration. The controller complies with the IEC 61000-4 test standard and the JB/T 7631-2005 production standard for electronic temperature controllers for transformers. Standard PT100 sensors can be replaced by fluorescent fiber optic sensors, whose measurement is not disturbed by electromagnetic interference.

See all specifications

Highlights

  • Adoption of accreditation standards: ISO9001:2008International Quality Management System Certification
  • Control error: ≤ ± 0.5 ºC
  • External dimensions: 400*320*100mm(Customizable)
  • Measuring Range: -30.0 ºC~240 ºC
  • Pass the test standard:: IEC61000-4:1995 International standard
  • Protection Level: IP54

See also