MD310T2.2B-INT
Compact 2.2 kW variable frequency drive for asynchronous motors

- Input current (A)
- 5.8
- Output Current
- 5.1
- Carrier frequency
- 0.5 kHz to 16 kHz
- Parameter backup
- ✔
Compact 2.2 kW variable frequency drive for asynchronous motors
Variable Frequency Drives (VFD)
Compact Inovance MD310T2.2B-INT 2.2 kW drive for controlling three-phase asynchronous motors at 380 V to 440 V, with V/f and sensorless vector control.
Inovance MD310T2.2B-INT is a 2.2 kW variable frequency drive (VFD) for controlling asynchronous motors. It is supplied from three-phase 380 V to 440 V and delivers an output current of 5.1 A for an input current of 5.8 A.
Main characteristics. Asynchronous motor control in V/f and SVC (sensorless vector control), maximum output frequency of 300 Hz in vector control and 500 Hz in V/f, speed stability accuracy of 1% in V/f and ±0.5% in SVC, torque control accuracy of ±5% in SVC, startup torque of 150% at 0.5 Hz in SVC. Carrier frequency from 0.5 kHz to 16 kHz. Overload capacity of 120% for 1 hour, 150% for 1 minute and 180% for 2 seconds. A built-in PID regulator supports process control, and a wobble function is available.
Analog inputs: 2 (0 V to 10 V or 0 mA to 20 mA), HDI pulse input 20 kHz and HDO pulse output 50 kHz. Digital inputs: 5 (DI1 to DI5), one digital output and one relay (NO/NC). External operating panel available in LED (MD310-KEY1) or LCD (MDKE9) versions, with MDCAB cables of 1.5 m, 3 m or 10 m. Positive and negative bus terminals provided.
Power and environment. Power dip ride-through, maintainable fan, IP20 protection rating, backplate mounting. Operating temperature from -10 °C to +50 °C, with derating between 40 °C and 50 °C, humidity below 95% RH non-condensing, maximum altitude of 3000 m with 1% derating per additional 100 m above 1000 m. Dimensions 108 x 128 x 158 mm. Safety certifications CE, EAC and KC.
Typical uses. Control of low-power pumps, fans and conveyors, and constant-setpoint process regulation thanks to the built-in PID, with integration into an existing Modbus RTU network through the RS485 port. This product is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MD310T2.2B-INT, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| IP rating | IP20 |
| ABZ encoder | ✖ |
| AC output reactor (-L) | ✖ |
| AI | 2 (0 VDC to 10 VDC/0 mA to 20 mA available, additional 1 AI (-10 V to 10 V) through IO card) |
| Altitude | Maximum 3000m. For altitudes above 1000 m, derate 1% for every additional 100 m. |
| AO | 1 (0 mA to 20 mA/0 V to 10 V), additional 1 AO (0 mA to 20 mA/0 V to 10 V) |
| Asynchronous motor | ✔ |
| Auxiliary power distribution cabinet (A) | ✖ |
| Brake function | ✖ |
| Braking unit (B) | ✔ |
| Cable for connecting an external operating panel | MDCAB (3m) MDCAB-10 (10m) MDCAB-1.5 (1.5m) |
| CANlink | Expansion card: MD310‑CANL |
| CANopen | ✖ |
| Carrier frequency | 0.5 kHz to 16 kHz |
| Control Mode | Asynchronous motor: V/f, SVC |
| DC reactor (-T) | ✖ |
| DI | 5 (DI1 to DI5), additional 5 DIs through IO card |
| DI/DO | ✖ |
| Dimensions (mm) | 108 (W) x 128 (H) x 158 (D) |
| DO | 1, additional 1 DO through IO card |
| Droop control | ✔ |
| Electromagnetic shorting | ✖ |
| EMC rating | External filter: C2 |
| EMC shield bracket | ✖ |
| EtherCAT | ✖ |
| Ethernet/IP | ✖ |
| External LCD operating panel | MDKE9 |
| External LED operating panel | MD310-KEY1 |
| Full closed-loop | ✖ |
| HDI | 20 kHz pulse input through DI5 |
| HDO | 50 kHz pulse output through FM |
| Humidity | Less than 95% RH, non-condensing |
| I/O expansion card | Expansion card: MD310-IO1 |
| Independent 24 V power supply | ✖ |
| India | For customers in India |
| Inovance 23-bit encoder | ✖ |
| Input current (A) | 5.8 |
| Installation Mode | Backplate mounting |
| Load distribution | ✖ |
| Maintainable fan | ✔ |
| Maximum output frequency | Vector control: 300 Hz; V/f control: 500 Hz |
| Modbus ASCII | ✖ |
| MODBUS RTU | ✔ |
| Modbus TCP | ✖ |
| Motor temperature sensor | Optional MD310-IO1 expansion card PT100, PT1000 |
| Mounting bracket of external LCD operating panel | CP600-BASE1 |
| Mounting bracket of external LED operating panel | ✖ |
| Mounting guide rail | ✖ |
| Number of expansion slots | 1 |
| Other Regions | For customers in all other regions |
| Output Current | 5.1 |
| Overload Capacity | 1 hour at 120% of the rated load; 1 minute at 150% of the rated load; 2 seconds at 180% of the rated load |
| Parameter backup | ✔ |
| Pluggable terminal | ✖ |
| Position Function | ✖ |
| Position synchronization | ✖ |
| Positioning expansion card | ✖ |
| Positive and negative bus terminals | ✔ |
| Power dip ride-through | √ |
| Power(kW) | 2.2 |
| PROFIBUS DP | ✖ |
| PROFINET | ✖ |
| Programming | ✖ |
| Relay | 1 (NO/NC), additional 1 relay through IO card |
| Reluctance motor | ✖ |
| Removal and installation | DIN guide rail-based installation is not supported. |
| Resolver | ✖ |
| Safety certification | CE, EAC, KC |
| Safety Function | ✖ |
| Secondary development | ✖ |
| Sin-Cos encoder | ✖ |
| Speed stability accuracy | V/f: 1% SVC: ±0.5% |
| Speed synchronization | ✖ |
| SSI encoder | ✖ |
| Startup torque | SVC: 0.5 Hz/150% V/f: 1.0 Hz/100% |
| Synchronous motor | ✖ (Only supported for MD310E) |
| Temperature | -10°C to +50°C (Derating is required for temperatures between 40℃ to 50℃.) |
| Tension control | ✖ |
| Through-hole mounting bracket | ✖ |
| Torque control accuracy | SVC: ±5% |
| Two/Four-quadrant AC drive | Two-quadrant |
| UVW output copper busbar | ✖ |
| Vibration Resistance | < 0.6 kg |
| Voltage class (V) | Three-phase AC 380 V to 440 V |
No specification matches.
Last verification : 2026-11-09
Official documents and the technical data recorded for MD310T2.2B-INT. For a missing document or a specific revision, our experts send it to you.
Compact Inovance MD310T2.2B-INT 2.2 kW drive for controlling three-phase asynchronous motors at 380 V to 440 V, with V/f and sensorless vector control.
| Parameter | Value |
|---|---|
| IP rating | IP20 |
| ABZ encoder | ✖ |
| AC output reactor (-L) | ✖ |
| AI | 2 (0 VDC to 10 VDC/0 mA to 20 mA available, additional 1 AI (-10 V to 10 V) through IO card) |
| Altitude | Maximum 3000m. For altitudes above 1000 m, derate 1% for every additional 100 m. |
| AO | 1 (0 mA to 20 mA/0 V to 10 V), additional 1 AO (0 mA to 20 mA/0 V to 10 V) |
| Asynchronous motor | ✔ |
| Auxiliary power distribution cabinet (A) | ✖ |
| Brake function | ✖ |
| Braking unit (B) | ✔ |
| Cable for connecting an external operating panel | MDCAB (3m) MDCAB-10 (10m) MDCAB-1.5 (1.5m) |
| CANlink | Expansion card: MD310‑CANL |
| CANopen | ✖ |
| Carrier frequency | 0.5 kHz to 16 kHz |
| Control Mode | Asynchronous motor: V/f, SVC |
| DC reactor (-T) | ✖ |
| DI | 5 (DI1 to DI5), additional 5 DIs through IO card |
| DI/DO | ✖ |
| Dimensions (mm) | 108 (W) x 128 (H) x 158 (D) |
| DO | 1, additional 1 DO through IO card |
| Droop control | ✔ |
| Electromagnetic shorting | ✖ |
| EMC rating | External filter: C2 |
| EMC shield bracket | ✖ |
| EtherCAT | ✖ |
| Ethernet/IP | ✖ |
| External LCD operating panel | MDKE9 |
| External LED operating panel | MD310-KEY1 |
| Full closed-loop | ✖ |
| HDI | 20 kHz pulse input through DI5 |
| HDO | 50 kHz pulse output through FM |
| Humidity | Less than 95% RH, non-condensing |
| I/O expansion card | Expansion card: MD310-IO1 |
| Independent 24 V power supply | ✖ |
| India | For customers in India |
| Inovance 23-bit encoder | ✖ |
| Input current (A) | 5.8 |
| Installation Mode | Backplate mounting |
| Load distribution | ✖ |
| Maintainable fan | ✔ |
| Maximum output frequency | Vector control: 300 Hz; V/f control: 500 Hz |
| Modbus ASCII | ✖ |
| MODBUS RTU | ✔ |
| Modbus TCP | ✖ |
| Motor temperature sensor | Optional MD310-IO1 expansion card PT100, PT1000 |
| Mounting bracket of external LCD operating panel | CP600-BASE1 |
| Mounting bracket of external LED operating panel | ✖ |
| Mounting guide rail | ✖ |
| Number of expansion slots | 1 |
| Other Regions | For customers in all other regions |
| Output Current | 5.1 |
| Overload Capacity | 1 hour at 120% of the rated load; 1 minute at 150% of the rated load; 2 seconds at 180% of the rated load |
| Parameter backup | ✔ |
| Pluggable terminal | ✖ |
| Position Function | ✖ |
| Position synchronization | ✖ |
| Positioning expansion card | ✖ |
| Positive and negative bus terminals | ✔ |
| Power dip ride-through | √ |
| Power(kW) | 2.2 |
| PROFIBUS DP | ✖ |
| PROFINET | ✖ |
| Programming | ✖ |
| Relay | 1 (NO/NC), additional 1 relay through IO card |
| Reluctance motor | ✖ |
| Removal and installation | DIN guide rail-based installation is not supported. |
| Resolver | ✖ |
| Safety certification | CE, EAC, KC |
| Safety Function | ✖ |
| Secondary development | ✖ |
| Sin-Cos encoder | ✖ |
| Speed stability accuracy | V/f: 1% SVC: ±0.5% |
| Speed synchronization | ✖ |
| SSI encoder | ✖ |
| Startup torque | SVC: 0.5 Hz/150% V/f: 1.0 Hz/100% |
| Synchronous motor | ✖ (Only supported for MD310E) |
| Temperature | -10°C to +50°C (Derating is required for temperatures between 40℃ to 50℃.) |
| Tension control | ✖ |
| Through-hole mounting bracket | ✖ |
| Torque control accuracy | SVC: ±5% |
| Two/Four-quadrant AC drive | Two-quadrant |
| UVW output copper busbar | ✖ |
| Vibration Resistance | < 0.6 kg |
| Voltage class (V) | Three-phase AC 380 V to 440 V |
Answers to the questions that the recorded characteristics of MD310T2.2B-INT can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Modbus ASCII": ✖.
Yes — recorded under "Ethernet/IP": ✖.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Compact 2.2 kW variable frequency drive for asynchronous motors




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MD310T2.2B-INT |
| Manufacturer | Inovance |
Variable Frequency Drives (VFD)
Three-phase AC variable frequency drive
Price on request
Variable Frequency Drives (VFD)
Industrial 690 V three-phase variable frequency drive IP54 · Ref. : SX-D64P0-EVA4
Price on request
Variable Frequency Drives (VFD)
Elevator AC drive 5.5 kW three-phase 380 V · Ref. : ME320LN-4005-SA-INT
Price on request
Variable Frequency Drives (VFD)
Integrated elevator drive controller with CAN bus communication
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details