Split core clamp-on current transformer for current measurement on equipment without dismantling the primary conductor. Used for energy consumption monitoring.
Rated Input Current; (穿芯P1-P2)200A
Rated Output Current; (S1-S2)66.7mA
Operating Frequency50~60Hz
Accuracy; (S1-S2)0.5
Dielectric Strength2.5V/2mA/60SEC(AC50HZ)
Insulation Resistance≥1000MΩ (额定电压500Vdc)
Product overview
Overview. The IVY Metering CTK clamp-on current transformer is a split core current transformer for current monitoring in electrical equipment. It fits around the conductor without dismantling the primary busbar.
Main characteristics. Transformation ratio 1:3000, rated primary input current of 200A, rated output current of 66.7mA, load resistor of 10Ω and accuracy class 0.5 on terminals S1-S2.
Dielectric strength and insulation. Dielectric strength of 2.5V/2mA/60SEC (AC 50Hz) and insulation resistance of at least 1000MΩ at 500Vdc.
Operating frequency. Operating range of 50 to 60Hz.
Typical uses. Monitoring and metering of equipment power consumption, electrical monitoring in distribution cabinets and measurements linked to energy management.
Integration. The transformer connects to a measuring or acquisition device on output terminals S1-S2. References and conditions are available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for CLAMP-CURRENT-TRANSFORMER, with where it comes from. Use the filters to find one quickly.
All specifications (8)
Characteristic
Value
Accuracy; (S1-S2)
0.5
Dielectric Strength
2.5V/2mA/60SEC(AC50HZ)
Insulation Resistance
≥1000MΩ (额定电压500Vdc)
Load Resistor
10Ω
Operating Frequency
50~60Hz
Rated Input Current; (穿芯P1-P2)
200A
Rated Output Current; (S1-S2)
66.7mA
Ratio; (N1-N2)
1:3000
No specification matches.
Last verification : 2026-10-31
Technical documentation
Official documents and the technical data recorded for CLAMP-CURRENT-TRANSFORMER. For a missing document or a specific revision, our experts send it to you.
Split core clamp-on current transformer for current measurement on equipment without dismantling the primary conductor. Used for energy consumption monitoring.
Rated Input Current; (穿芯P1-P2)200A
Rated Output Current; (S1-S2)66.7mA
Operating Frequency50~60Hz
Accuracy; (S1-S2)0.5
Dielectric Strength2.5V/2mA/60SEC(AC50HZ)
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy; (S1-S2)
0.5
Dielectric Strength
2.5V/2mA/60SEC(AC50HZ)
Insulation Resistance
≥1000MΩ (额定电压500Vdc)
Load Resistor
10Ω
Operating Frequency
50~60Hz
Rated Input Current; (穿芯P1-P2)
200A
Rated Output Current; (S1-S2)
66.7mA
Ratio; (N1-N2)
1:3000
Applications and use cases
Architectures in which CLAMP-CURRENT-TRANSFORMER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar panels produce most when nobody is home, and the surplus goes to the grid. A battery with its inverter stores this energy and returns it in the evening, with a meter measuring what the home draws
To check
Panel power and the inverter compatibility of the battery
Usable capacity compared with the evening and night consumption
Local grid connection rules for balcony and home systems
Associated system blocks
InvertersBatteryMetering
Need a complete solution?
Send a request for CLAMP-CURRENT-TRANSFORMER and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details