EM619002 bidirectional DC energy meter that monitors voltage, current, power and forward and reverse energy on a DC circuit, for example a battery system.
Product overview
IVY Metering EM619002 DC energy meter. The IVY Metering EM619002 is a bidirectional DC energy meter that measures voltage, current, power and energy in both directions of a DC circuit, as well as energy over a set period. It is designed for telecom base stations, DC charging piles, BESS, photovoltaic arrays and data centers.
Measurement and display. The meter shows DC power, current, voltage and tariff energy on an LCD, with automatic data scrolling every 5 seconds or page turning by an external button. The backlight lights up when the page button is pressed. Maximum and minimum voltage and current values are recorded.
Communication and protocols. The RS485 interface supports Modbus-RTU and DLT645 protocols at the same time, allowing parameter setting and reading or writing of power data from a PLC or a computer.
Alarms and events. A relay alarm output and a digital input are built in. Over-voltage and over-current thresholds can be set, and the device stores the last 20 events of over-voltage, under-voltage and over-current.
Electrical characteristics. Maximum measuring current of 2000 A with an external shunt (to be ordered separately), DC measuring voltage 5 V to 1000 V, auxiliary power supply 9 to 60 VDC, accuracy Cl1.0, IP51 protection. The real-time clock is kept for about 5 years when the meter is powered off, thanks to a battery.
Integration. Four tariffs with 8 time slots allow billing by period. The meter mounts on a DIN rail and fits a measurement and control system with a controller or supervision software.
EM619002 bidirectional DC energy meter that monitors voltage, current, power and forward and reverse energy on a DC circuit, for example a battery system.
RateFour Tariffs with 8 Time Slots
2. Datasheet extract (recorded values)
Parameter
Value
Communication
Supports RS485 communication with protocol DTL645, which allows parameters setting and read or write power data
Event record
The device itself stores the last 20 records when overvoltage, undervoltage, and overcurrent occur
Rate
Four Tariffs with 8 Time Slots
Applications and use cases
Architectures in which EM619002 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for EM619002 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details