IVY Metering split core current transformer with openable core, class 0.5, 20 VA rated burden, for current measurement outdoors on 660 V rated voltage, 50/60 Hz.
Rated-Input Current — 200A — 800A1500A
Rated Output Current; (S1-S2)5A
Frequency50/60Hz
Accuracy; (S1-S2)0.5
额定输入电流; (穿芯) — 500A — 1500A — 3000A2000A
Coil Ratio; (N1:N2) — 1:40 — 1:1601:300
Product overview
Overview. The IVY Metering OC 0.66-130×40II is a split core current transformer with an openable core, designed for current measurement on distribution and metering networks. It has a rated voltage of 660 V and operates at 50/60 Hz.
Main characteristics. The product offers a rated primary current of 200 A, 800 A or 3000 A for a rated secondary current of 5 A, with coil ratios of 1:40, 1:160 and 1:300. Its accuracy class is 0.5 and its rated burden is 20 VA, with 2.5 VA, 10 VA and 15 VA loads in the configuration variants. The dark blue housing is flame retardant to V0 or V1 and withstands 120 °C.
Insulation and environment. The withstand voltage between primary and secondary is 3000 Vac (1 mA, 1 min) and the insulation resistance is at least 100 MΩ at 500 Vdc. The insulation class is E. The product complies with RoHS 2.0, operates between −30 °C and +120 °C and can be used at altitudes up to 3000 m.
Typical uses. This openable-core transformer clamps onto an existing conductor without interrupting the circuit, suiting current measurement in outdoor distribution cabinets and metering panels.
Architectures in which HIGH-ACCURACY-CURRENT-TRANSFORMER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Associated system blocks
Energy metersCurrent sensorsData collection
Need a complete solution?
Send a request for HIGH-ACCURACY-CURRENT-TRANSFORMER and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productIVY Metering
HIGH-ACCURACY-CURRENT-TRANSFORMER
Split core current transformer class 0.5 for outdoor use
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details