IM901D
Two-pole latching relay 90 A with single or double coil

- Max. Switching Current
- 90A
- Coil Voltage
- 6~48VDC
- Contact Form
- 2A/B
- Contact Material
- AgSnO2
Two-pole latching relay 90 A with single or double coil
Two-pole bistable latching relay with pulse-driven coil, switching loads up to 90 A at 250 VAC, used notably in smart meters and EV chargers.
Overview. The IVY Metering IM901D is a two-pole magnetic latching relay available in single-coil and double-coil versions. It is a bistable relay designed for power switching.
Main characteristics. The relay supports a maximum switching current of 90 A and a maximum switching power of 22500 VA, at a maximum switching voltage of 250 VAC. The contact form is 2A/B, the contact material is AgSnO2, and the coil voltage ranges from 6 to 48 VDC. Contact resistance is 0.8 mΩ or less, with a pick-up time and a release time of 30 ms each. A dielectric strength of 4 kV is provided between coil and contacts.
Endurance and temperature rise. Electrical endurance is 10000 cycles and mechanical endurance is 100000 cycles. Temperature rise is 55 K or less at an ambient temperature of 40 °C. The coil is driven by an instantaneous pulse, without heating.
Compliance. The relay complies with IEC 62055-31 UC2/UC3.
Typical uses. Smart meters (IC card, prepaid, single-phase and three-phase meters), reactive power compensation, intelligent control (solar street lighting, smart home, automation equipment) and new energy applications (EV chargers, PV inverters).
Availability. The IM901D is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for IM901D, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Coil Voltage | 6~48VDC |
| Contact Form | 2A/B |
| Contact Material | AgSnO2 |
| Electrical Endurance | 10000 Cycles |
| Max. Switching Current | 90A |
| Max. Switching Power | 22500VA |
| Max. Switching Voltage | 250VAC |
| Mechanical Endurance | 100000 Cycles |
No specification matches.
Last verification : 2026-10-31
Official documents and the technical data recorded for IM901D. For a missing document or a specific revision, our experts send it to you.
Two-pole bistable latching relay with pulse-driven coil, switching loads up to 90 A at 250 VAC, used notably in smart meters and EV chargers.
| Parameter | Value |
|---|---|
| Coil Voltage | 6~48VDC |
| Contact Form | 2A/B |
| Contact Material | AgSnO2 |
| Electrical Endurance | 10000 Cycles |
| Max. Switching Current | 90A |
| Max. Switching Power | 22500VA |
| Max. Switching Voltage | 250VAC |
| Mechanical Endurance | 100000 Cycles |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Two-pole latching relay 90 A with single or double coil

India BIS Standard Smart Meter On Off 90A Latching Relays with Single/Two/Three Phase

90A 250VAC Single Dual Coil 5VDC 6VDC 12VDC Bistable Magnetic Latching Relay Switch

UC2 120A High Current Contact Switching 3 Phase Pulse Latching Relay for Metering Control

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | IM901D |
| Manufacturer | IVY Metering |
Latching Relays
Smart capacitor latching relay 60 A
Price on request
Latching Relays
DIN Rail Latching Relay with Energy Monitoring
Price on request
Latching Relays
Prepaid EV charger controller 32A 22kW three-phase
Price on request
Latching Relays
Latching relay for smart capacitor 100 A
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details