D1C9002-01 – Wireless CT clamp current monitoring sensor with Wi-Fi and Bluetooth

Wireless CT clamp current monitoring sensor with Wi-Fi and Bluetooth

EVSE Components

  • -20 ~ +60℃
  • 5(100)A
  • 5%Ib(250mA)
  • 0.04%Ib(4mA)
Manufacturer part number
WIRELESS-CURRENT-SENSOR
Manufacturer
IVY Metering
Temperature range
-20 ~ +60℃
Current
5(100)A

Wireless CT clamp current sensor from IVY Metering with Wi-Fi and Bluetooth communication, for energy monitoring, including current monitoring on electric vehicle charging stations.

Product overview

Overview. The D1C9002-01 from IVY Metering is a wireless CT clamp current sensor with Wi-Fi and Bluetooth communication. It measures current, voltage, power and power factor and reports data in real time without communication wiring.

Main characteristics. Current range of 5 to 100 A, starting current of 0.04% Ib (4 mA), minimum current of 5% Ib (250 mA), measurement accuracy of 2%, rated frequency of 50 to 60 Hz, pulse constant of 1000 imp/kWh. Measurement is bidirectional: forward and reverse current and power are measured.

Installation. Split-core structure that is easy to disassemble, with a threading hole diameter of up to φ12 mm. Installation requires the power to be turned off.

Interfaces and connectivity. Modbus (RTU and TCP), Http/Json protocols and OTA update support. Data can be reported to a cloud platform via Modbus and other protocols, and viewed remotely over the network.

Power and environment. Voltage input of 230 V (±20%), temperature range of -20 to +60 °C.

Typical uses. Real-time monitoring of the output current of electric vehicle charging stations, energy management in smart building and smart grid systems, current monitoring of AC motors, lighting and air compressors in industrial automation.

See all specifications

Highlights

  • Current: 5(100)A
  • Measurement Accuracy: 2%
  • Minimum current: 5%Ib(250mA)
  • Protocol: Modbus(RTU&TCP), Http/Json, and Support OTA
  • Pulse Constant: 1000imp/kwh
  • Rated Frequency: 50~60Hz

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote