MEMORATOR LIGHT HS
CAN data logger USB with 1 channel

- Temp. Range
- -40 °C to 85 °C
- Interfaces PC
- USB
- Error Frame Detection
- Yes
- Error Frame Generation
- No
CAN data logger USB with 1 channel
A CAN logger for tracing vehicle bus traffic over USB with 1 channel.
Memorator Light HS bus access. Kvaser’s Memorator Light HS records 1-channel CAN traffic for vehicle diagnostics.
Traffic and timing. The bus operates across 10 - 1000 kbps. Timestamp resolution of 2 µs helps reconstruct captured frame order. The bus-side connector is DSUB 9.
Bus diagnostics and isolation. Error-frame detection exposes bus faults during monitoring. Silent mode lets the operator monitor traffic without normal transmission on the bus.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MEMORATOR LIGHT HS, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Bit Rate (kbps) | 10 - 1000 kbps |
| Channels | 1 |
| Connectors | DSUB 9 |
| Error Frame Detection | Yes |
| Error Frame Generation | No |
| Galvanic Isolation | No |
| Height | 22 mm |
| Interfaces PC | USB |
| IP Class | IP40 |
| Length | 115 mm |
| Messages Per Second Receive | 6000 mps |
| Operating System | Windows 7 (IA-32 and x86-64), Windows 8 (IA-32 and x86-64), Windows 10 (IA-32 and x86-64), Windows 11 (x86-64), Linux |
| Regulatory Compliance | CE, FCC |
| Silent Mode | Yes |
| t script | No |
| Temp. Range | -40 °C to 85 °C |
| Timestamp Resolution (µs) | 2 µs |
| Weight | 150 g |
| Width | 46 mm |
No specification matches.
Last verification : 2026-11-25
Official documents and the technical data recorded for MEMORATOR LIGHT HS. For a missing document or a specific revision, our experts send it to you.
A CAN logger for tracing vehicle bus traffic over USB with 1 channel.
| Parameter | Value |
|---|---|
| Bit Rate (kbps) | 10 - 1000 kbps |
| Channels | 1 |
| Connectors | DSUB 9 |
| Error Frame Detection | Yes |
| Error Frame Generation | No |
| Galvanic Isolation | No |
| Height | 22 mm |
| Interfaces PC | USB |
| IP Class | IP40 |
| Length | 115 mm |
| Messages Per Second Receive | 6000 mps |
| Operating System | Windows 7 (IA-32 and x86-64), Windows 8 (IA-32 and x86-64), Windows 10 (IA-32 and x86-64), Windows 11 (x86-64), Linux |
| Regulatory Compliance | CE, FCC |
| Silent Mode | Yes |
| t script | No |
| Temp. Range | -40 °C to 85 °C |
| Timestamp Resolution (µs) | 2 µs |
| Weight | 150 g |
| Width | 46 mm |
Answers to the questions that the recorded characteristics of MEMORATOR LIGHT HS can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Interfaces PC": USB.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
CAN data logger USB with 1 channel

Kvaser

Kvaser

Kvaser

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MEMORATOR LIGHT HS |
| Manufacturer | Kvaser |
Vehicle Data Loggers
CAN FD logger, 2 channels with DSUB 9
Price on request
Vehicle Data Loggers
CAN FD logger, 5 channels with Molex 51021 PicoBladeTM
Price on request
Vehicle Data Loggers
CAN logger, 2 channels with DSUB 9
Price on request
Vehicle Data Loggers
CAN FD logger, 2 channels with Molex 51021 PicoBladeTM
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details