4105A-H
2- and 3-pole earth resistance tester with LCD display

- Didplay range
- 0.0 to 199.9V
- Measuring Range
- 0.00 to 1999 &Omega
- Accuracy
- ±1 %rdg ±4dgt
- Accuracy — ±2%rdg±0.1&Omega
- ± 2 %rdg ±3dgt
2- and 3-pole earth resistance tester with LCD display
Installation and Earth Testers
2- and 3-pole earth resistance tester in a hard case, with LCD display, designed to IEC 61010-1 for earth resistance and earth voltage measurement.
Kyoritsu KEW 4105A-H earth tester. the KEW 4105A-H is a 2- and 3-pole earth resistance tester in the hard case version, in the installation and earth testers category. Main characteristics — The large LCD digital display is easy to read. The instrument measures earth resistance from 0.00 to 1999 Ω and earth voltage from 0.0 to 199.9 V, with an accuracy of ±1 %rdg ±4dgt for voltage and ±2 %rdg ±3dgt for resistance according to the data. The 2 mA measuring current allows earth resistance tests without tripping earth leakage current breakers in the circuit under test. The circuit design keeps the influence of earth voltage and of the auxiliary earth spike resistance to a minimum. Power and environment — The instrument runs on six R6 (AA) 1.5 V batteries. It is overload protected (280 V AC for 10 seconds on earth resistance, 300 V AC for 1 minute on earth voltage). The case is dust and drip proof to IP54 and weighs approximately 550 g with batteries and case lid. Typical uses — This tester is intended for checking earthing installations and earth electrodes. It complies with IEC 61010-1 (CAT III 300 V, pollution degree 2), IEC 61010-2-030, IEC 61557-1 and 5 and IEC 60529 (IP54). It is supplied with test leads 7095A, simplified measurement probe 7127B, auxiliary earth spikes 8032, shoulder strap 9121 and hard carrying case 9165. Atlas Electronics offers this tester on quotation.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 4105A-H, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accessories | 7095A (Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)); 7127B (Simplified measurement probe); 8032 (Auxiliary earth spikes[2 spikes/1set]); 9121 (shoulder strap); 9165 (Carrying case [Hard]); R6 (AA) × 6, Instruction Manual |
| Accuracy | ±1 %rdg ±4dgt |
| Accuracy — ±2%rdg±0.1&Omega | ± 2 %rdg ±3dgt |
| Applicable Standards | IEC 61010-1 CAT III 300V Pollution Degree 2,; IEC 61010-2-030, IEC 61557-1,5,; IEC 60529 (IP54) |
| Didplay range | 0.0 to 199.9V |
| Didplay range — 0.00 to 19.99 &Omega — 0.0 to 199.9 &Omega | 0.0 to 199 9 &Omega |
| Dimension | 105(L) × 158(W) × 70(D)mm (including case lid) |
| Earth resistance; measurement — 20&Omega — 200&Omega | 2000&Omega |
| Measuring Range | 0.00 to 1999 &Omega |
| Optional Accessories | 7245A (Precision measurement cord set); 8259 (Adapter for measurement terminal); 9084 (Carrying case) |
| Overload Protection | Earth Resistance: 280V AC (10 seconds); Earth Voltage: 300V AC (1 minute) |
| Power Source | R6 (AA) (1.5V) × 6 |
| Product Catalog | KEW 4105A Product Catalog (English)(1.87 MB) |
| Weight | Approx. 550g (including batteries and case lid) |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for 4105A-H. For a missing document or a specific revision, our experts send it to you.
2- and 3-pole earth resistance tester in a hard case, with LCD display, designed to IEC 61010-1 for earth resistance and earth voltage measurement.
| Parameter | Value |
|---|---|
| Accessories | 7095A (Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)); 7127B (Simplified measurement probe); 8032 (Auxiliary earth spikes[2 spikes/1set]); 9121 (shoulder strap); 9165 (Carrying case [Hard]); R6 (AA) × 6, Instruction Manual |
| Accuracy | ±1 %rdg ±4dgt |
| Accuracy — ±2%rdg±0.1&Omega | ± 2 %rdg ±3dgt |
| Applicable Standards | IEC 61010-1 CAT III 300V Pollution Degree 2,; IEC 61010-2-030, IEC 61557-1,5,; IEC 60529 (IP54) |
| Didplay range | 0.0 to 199.9V |
| Didplay range — 0.00 to 19.99 &Omega — 0.0 to 199.9 &Omega | 0.0 to 199 9 &Omega |
| Dimension | 105(L) × 158(W) × 70(D)mm (including case lid) |
| Earth resistance; measurement — 20&Omega — 200&Omega | 2000&Omega |
| Measuring Range | 0.00 to 1999 &Omega |
| Optional Accessories | 7245A (Precision measurement cord set); 8259 (Adapter for measurement terminal); 9084 (Carrying case) |
| Overload Protection | Earth Resistance: 280V AC (10 seconds); Earth Voltage: 300V AC (1 minute) |
| Power Source | R6 (AA) (1.5V) × 6 |
| Product Catalog | KEW 4105A Product Catalog (English)(1.87 MB) |
| Weight | Approx. 550g (including batteries and case lid) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
2- and 3-pole earth resistance tester with LCD display

MODEL

KEW

KEW

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 4105A-H |
| Manufacturer | Kyoritsu |
Installation and Earth Testers
Single and three-phase ZigBee electrical metering module
Price on request
Installation and Earth Testers
Multifunction installation tester with loop and RCD testing · Ref. : KEW_6016
Price on request
Installation and Earth Testers
Advanced earth resistance and soil resistivity tester · Ref. : UT572
Price on request
Installation and Earth Testers
Residual current device (RCD) tester with trip time measurement · Ref. : KEW_5410
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details