KEW_3022
Digital insulation resistance tester with auto-ranging 600 V

- Output short circuit current
- 1.5mA max
- Rated Current
- DC 1 - 1.2mA
- Accuracy
- ±2%rdg±6dgt
- Auto-ranging
- 40.00/400.0&Omega
Digital insulation resistance tester with auto-ranging 600 V
Kyoritsu KEW 3022 digital insulation resistance tester for measuring insulation at 50, 100, 250 or 500 V, with AC voltage measurement up to 600 V.
Overview. The Kyoritsu KEW 3022 is a digital insulation resistance tester with auto-ranging, designed for insulation resistance measurement and AC voltage measurement.
Main characteristics. Test voltages of 50, 100, 250 and 500 V, first effective measuring range from 0.2 MΩ to 200 MΩ depending on the test voltage, measuring range up to 2000 MΩ, accuracy of ±2 % of reading ±6 digits, output short-circuit current of 1.5 mA maximum. The tester also measures AC voltages from 20 to 600 V (50/60 Hz) and DC voltages of ±20 to ±600 V.
Safety and compliance. Compliant with IEC 61010-1 CAT III 600 V, IEC 61557-1, 2 and 4, and the EMC standard IEC 61326-1. Protection rating IEC 60529 IP40. Quick-acting ceramic fuse 0.5 A / 600 V.
Power and dimensions. Powered by six R6 (AA) or LR6 batteries, dimensions 105 × 158 × 70 mm for approximately 600 g.
Typical uses. Insulation checks on electrical installations and equipment before commissioning or during maintenance, using the supplied accessories (7150A remote control switch set, 9121 shoulder strap) and optional accessories (7115 extension probe, 8016 hook-type probe, 9089 carrying case).
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_3022, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC Voltage Range | AC 20 - 600V (50/60Hz) DC -20 - -600V/+20 - +600V |
| Accessories | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual |
| Accuracy | ±2%rdg±6dgt |
| Applicable Standards | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) |
| Auto-ranging | 40.00/400.0&Omega |
| Dimension / Weight | 105(L) × 158(W) × 70(D)mm / 600g approx. |
| First effective measuring range | 0.2 - 20MΩ (50/100V) 0.2 - 40MΩ (250V) 0.2 - 200MΩ (500V) |
| Fuse | Quick acting ceramic fuse 0.5A/600V (Ø 6.35×32mm) |
| Measuring range(Auto-ranging) | 4.000/40.00/200.0MΩ (50/100V) 4.000/40.00/400.0/2000MΩ (250/500V) |
| Mid-scale value | 5MΩ (50/100/250V) 50MΩ (500V) |
| Optional Accessories | 7115 (Extension Probe), 8016 (Hook type prod), 8923 (Fuse [0.5A/600V]), 9089 (Carrying Case) |
| Output short circuit current | 1.5mA max |
| Output voltage on open circuit | 5V±20% |
| Power Source | R6 × 6 or LR6 × 6 |
| Product Catalog | KEW 3021/3022/3023 Product Catalog (English)(379.85 KB) |
| Rated Current | DC 1 - 1.2mA |
| Second effective measuring range lower | 0.110 - 0.199M&Omega |
| Second effective measuring range upper | 20.01 - 200.0MΩ (50/100V) 40.01 - 2000MΩ (250V) 200.1 - 2000MΩ (500V) |
| Test voltage | 50/100/250/500V |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_3022. For a missing document or a specific revision, our experts send it to you.
Kyoritsu KEW 3022 digital insulation resistance tester for measuring insulation at 50, 100, 250 or 500 V, with AC voltage measurement up to 600 V.
| Parameter | Value |
|---|---|
| AC Voltage Range | AC 20 - 600V (50/60Hz) DC -20 - -600V/+20 - +600V |
| Accessories | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual |
| Accuracy | ±2%rdg±6dgt |
| Applicable Standards | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) |
| Auto-ranging | 40.00/400.0&Omega |
| Dimension / Weight | 105(L) × 158(W) × 70(D)mm / 600g approx. |
| First effective measuring range | 0.2 - 20MΩ (50/100V) 0.2 - 40MΩ (250V) 0.2 - 200MΩ (500V) |
| Fuse | Quick acting ceramic fuse 0.5A/600V (Ø 6.35×32mm) |
| Measuring range(Auto-ranging) | 4.000/40.00/200.0MΩ (50/100V) 4.000/40.00/400.0/2000MΩ (250/500V) |
| Mid-scale value | 5MΩ (50/100/250V) 50MΩ (500V) |
| Optional Accessories | 7115 (Extension Probe), 8016 (Hook type prod), 8923 (Fuse [0.5A/600V]), 9089 (Carrying Case) |
| Output short circuit current | 1.5mA max |
| Output voltage on open circuit | 5V±20% |
| Power Source | R6 × 6 or LR6 × 6 |
| Product Catalog | KEW 3021/3022/3023 Product Catalog (English)(379.85 KB) |
| Rated Current | DC 1 - 1.2mA |
| Second effective measuring range lower | 0.110 - 0.199M&Omega |
| Second effective measuring range upper | 20.01 - 200.0MΩ (50/100V) 40.01 - 2000MΩ (250V) 200.1 - 2000MΩ (500V) |
| Test voltage | 50/100/250/500V |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Digital insulation resistance tester with auto-ranging 600 V

KEW 3021

KEW 3023A

KEW 3021A

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_3022 |
| Manufacturer | Kyoritsu |
Insulation Resistance Testers
High Voltage Insulation Resistance Tester 2500 V · Ref. : KEW_3025A
Price on request
Insulation Resistance Testers
EV insulation resistance tester for high voltage systems · Ref. : ITS100
Price on request
Insulation Resistance Testers
Insulation Resistance Tester Series with PI and DAR · Ref. : UT510
Price on request
Insulation Resistance Testers
1000 V digital insulation resistance tester with continuity test · Ref. : KEW_3023A
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details