KEW 8115 – AC/DC current clamp sensor for digital multimeters

AC/DC current clamp sensor for digital multimeters

Current Transformers Sensors

  • ±1.2%rdg±0.4mV (*)
  • Max. Ø 12mm
  • Approx. 1,200mm
  • 127(L)×42(W)×22(D) mm
Manufacturer part number
KEW_8115
Manufacturer
Kyoritsu
Conductor size
Max. Ø 12mm
Cord Length
Approx. 1,200mm

Kyoritsu KEW 8115 clamp sensor for AC and DC current measurement, compatible with digital multimeters. Conductor size up to 12 mm.

Product overview

Overview. The Kyoritsu KEW 8115 is an AC/DC current clamp sensor designed to be used with a digital multimeter. It measures alternating and direct current on a conductor up to 12 mm in diameter.

Main characteristics. Measuring range of 0.1 to 130 Arms (185 A peak) in AC and 0 to ±180 A in DC. The output delivers 10 mV/A in both AC and DC, with an output impedance of approximately 10 Ω or less. Accuracy is ±1.2 %rdg ±0.4 mV at 50/60 Hz and ±2.5 %rdg ±0.4 mV from 40 Hz to 1 kHz, defined after zero adjustment on the multimeter.

The device runs on two AAA alkaline LR03 batteries (DC 3 V), for approximately 40 hours of continuous use. A red LED flashes to signal a low battery (2.2 V ±0.2 V or less), and automatic power-off occurs at 1.9 V ±0.2 V.

Safety and environment. Compliant with IEC 61010-1 (CAT III 300 V, pollution degree 2), IEC 61010-2-032 and IEC 61326-1. Withstand voltage of 3540 V AC (RMS 50/60 Hz) for 5 seconds. Operating range from -10 to 55 °C, relative humidity 85% or less without condensation.

Dimensions and supply. 127 × 42 × 22 mm, approximately 140 g. Supplied accessories: model 9095 carrying case, two LR03 batteries and instruction manual.

See all specifications

Highlights

  • Accuracy — ±1.2%rdg±0.4mV (50/60Hz); ±2.5%rdg±0.4mV (40 to 1kHz): ±1.2%rdg±0.4mV (*)
  • Cord Length: Approx. 1,200mm
  • Dimension: 127(L)×42(W)×22(D) mm
  • Measuring range — AC 0.1 to 130Arms (185Apeak): DC 0 to ±180A
  • Output voltage — AC 10mV/A: DC 10mV/A
  • Weight: Approx. 140g

Typical applications

Derived from the part category, not a compatibility statement.