Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.

CE53S-Φ16 -3002-DC3 – High-temperature inductive sensor for material detection, 8 mm range

High-temperature inductive sensor for material detection, 8 mm range

General Industrial Sensors & Transmitters

Manufacturer part number
CE53
Manufacturer
Lanbao

Target detection sensor for high-temperature environments, Lanbao CE53 3002 series, with a cylindrical detection head and sensitivity adjustment for dispensing equipment.

Product overview

Lanbao CE53 3002 high-temperature detection sensor — the CE53 3002 series from Shanghai Lanbao Sensor Technology groups material detection sensors whose detection head withstands up to 250 ℃.

Main characteristics. adjustable distance of 8 mm, hysteresis of 3 to 20%, switching frequency of 0.3 Hz, repetitive error of 5% or less, load current of 250 mA or less and residual voltage of 2.5 V or less.

Outputs and connection. NO/NC outputs depending on model, NPN version reference CE53SN08MNC 3002 and PNP version reference CE53SN08MPO 3002. Amplifier connected by a 2 m PVC cable, detection head connected by a 1 m Teflon single-core shielded cable.

Power and protection. supply voltage of 18 to 36 VDC, consumption current of 100 mA or less, protection against short circuit, overload and reverse polarity. Red power indicator and green output indicator.

Environment and construction. ambient temperature of 0 to +60 ℃ for the amplifier, IP rating from IP54 to IP64, PA6 amplifier housing, Teflon and stainless steel sensor head, withstands 500 V AC at 50/60 Hz for 60 s, insulation resistance of 50 MΩ or more at 500 VDC and vibration resistance of 1.5 mm complex amplitude between 10 and 50 Hz for 2 hours in each of the X, Y and Z directions.

Typical uses. target detection in high-temperature environments, notably on dispensing equipment. Reference target in ST45 carbon steel with inner diameter greater than 20 mm and 1 mm ring thickness.

Integration. non-flush installation (contact use), amplifier dimensions 95.5 × 55 × 22 mm and head Φ16 × 100 mm, sensitivity adjusted with the supplied slotted screwdriver.

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote