The Lanbao FT22-DC2 is a 3-wire DC reed sensor with 10 to 30 VDC supply and IP67 protection, designed for position detection in industrial environments.
Supply voltage10… 30 VDC
Load Current≤ 50mA
Switching Frequency200Hz
Ambient temperature- 10...70℃
Connection Type2m PVC cable
Dimension14.2*15*33mm
Product overview
Overview. The Lanbao FT22-DC2 is a DC 3-wire reed proximity sensor. It is offered with NO output (model FT22DLO) or NO+NC output (model FT22DLR), with a yellow indicator LED.
Main characteristics. Supply voltage of 10 to 30 VDC, load current up to 50 mA, residual voltage of 2.5 VDC or less and switching frequency of 200 Hz. The PBT housing measures 14.2 × 15 × 33 mm.
Connection and protection. 2 m PVC cable. Protection degree IP67. Insulation resistance of 50 MΩ or more at 500 VDC and withstand voltage of 1000 V AC 50/60 Hz for 60 s.
Operating conditions. Ambient temperature from -10 to 70 °C, humidity from 35 to 95 %RH.
Vibration resistance. Complex amplitude of 1.5 mm from 10 to 50 Hz, tested for 2 hours in each of the X, Y and Z directions.
Typical uses. Position detection of cylinders or moving parts in industrial equipment, provided the output signal is compatible with the controller or PLC.
The Lanbao FT22-DC2 is a 3-wire DC reed sensor with 10 to 30 VDC supply and IP67 protection, designed for position detection in industrial environments.
Supply voltage10… 30 VDC
Load Current≤ 50mA
Switching Frequency200Hz
Ambient temperature- 10...70℃
Connection Type2m PVC cable
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
10… 30 VDC
Ambient temperature
- 10...70℃
Connection Type
2m PVC cable
Dimension
14.2*15*33mm
Environment Humidity
35...95%RH
Housing Material
PBT
Indicator
Yellow LED
Insulation Resistance
≥ 50MΩ (500VDC)
Load Current
≤ 50mA
NO
FT22DLO
NO+NC
FT22DLR
Protection degree
IP67
Residual voltage
≤ 2.5VDC
Switching Frequency
200Hz
Vibration resistant
Complex amplitude 1.5mm 10… 50Hz; (2 hours each in X, Y, and Z directions)
Withstand Voltage
1000V/AC 50/60Hz 60s
Integration
Points to check before using FT22-DC2 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 10… 30 VDC.
Power and communication
Supply voltage
10… 30 VDC
Load Current
≤ 50mA
Residual voltage
≤ 2.5VDC
Withstand Voltage
1000V/AC 50/60Hz 60s
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 10… 30 VDC.
Applications and use cases
Architectures in which FT22-DC2 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details