The Lanbao FY18 is an M18 flush-mount inductive sensor with NPN or PNP output, designed to detect metal parts and measure gear rotation speed.
Hysteresis range1... 15%
Supply voltage10… 30 VDC
Consumption Current≤ 15mA
Load Current≤ 200mA
Switching Frequency25KHz
Ambient temperature-25...70℃
Product overview
Overview. The Lanbao FY18 is an M18 flush-mount inductive sensor manufactured by Shanghai Lanbao Sensor Technology, part of the gear speed measurement series.
Main characteristics. Sensing distance of 2 mm, switching frequency of 25 kHz, hysteresis range of 1 to 15%, repetitive error of 3% or less, switch point offset of ±10% or less. The housing is made of nickel copper alloy. A yellow LED indicates the output state.
Outputs and connection. NPN version (FY18DNC) and PNP version (FY18DPO). Connection by 2 m PVC cable or M12 connector. Load current of 200 mA or less, consumption current of 15 mA or less, residual voltage of 2.5 VDC or less.
Power and environment. Supply voltage of 10 to 30 VDC. Protection against short circuit, overload, surge and reverse polarity. Ambient temperature range of -25 to 70 °C, minimum operating temperature of -20 °C, humidity of 35 to 95% RH. Protection degree IP67. Insulation resistance of 50 MΩ or more (500 VDC), withstand voltage of 1000 VAC 50/60 Hz for 60 s. Vibration resistance: complex amplitude of 1.5 mm at 10 to 50 Hz, 2 hours in each of the X, Y and Z directions.
Typical uses. Detection of metal parts and gear rotation speed measurement, in environments subject to vibration and humidity.
Integration. Flush mounting, dimension M18 x 1 x 50 mm, compatible with PLCs and control systems accepting an NPN or PNP transistor output.
Complex amplitude 1.5mm 10… 50Hz(2 hours each in X, Y, and Z directions)
Withstand Voltage
1000/AC 50/60Hz 60s
Integration
Points to check before using FY18 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 10… 30 VDC.
Power and communication
Supply voltage
10… 30 VDC
Consumption Current
≤ 15mA
Load Current
≤ 200mA
Residual voltage
≤ 2.5VDC
Withstand Voltage
1000/AC 50/60Hz 60s
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 10… 30 VDC.
Applications and use cases
Architectures in which FY18 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details