Lanbao inductive sensor with NAMUR output and M12 connector, powered at 8.2 VDC, for non-contact detection of metallic targets with a 40 mm or 50 mm sensing distance.
Supply voltage8.2 VDC
Switching frequency [F]100 Hz/100Hz
Repeat accuracy [R]≤ 3%
Dimensions40*80*104mm
MountingFlush/Nonflush
Ambient Humidity35...95%RH
Product overview
Overview. The Lanbao LE80XZ-E2-NAMUR is an inductive sensor with NAMUR output, in a PBT housing measuring 40 × 80 × 104 mm. It detects metallic targets without contact.
Main characteristics. Rated distance Sn of 40 mm or 50 mm, assured distance Sa of 0…32 mm or 0…40 mm, hysteresis of 1…20 %, repeat accuracy of 3 % or less, switch-point drift of ±10 % or less, switching frequency of 100 Hz. Standard target Fe120 × 120 × 1 t / Fe150 × 150 × 1 t. Flush or non-flush mounting.
Connection and protection. M12 connector, degree of protection IP67. Output current of 1 mA or less when triggered and 2.2 mA or more when not triggered.
Power and environment. Supply voltage 8.2 VDC. Ambient temperature −25 °C to 70 °C, minimum operating temperature −20 °C, ambient humidity 35 to 95 % RH. Vibration resistance 10 to 50 Hz (1.5 mm). Insulation resistance above 50 MΩ (500 VDC).
Typical uses. Position detection and counting of metallic parts on automation lines, in humid environments or where vibration is present, thanks to its IP67 rating.
Integration. The NAMUR output suits NAMUR-compatible amplifiers and inputs. Minimum load resistance 1 kΩ.
Lanbao inductive sensor with NAMUR output and M12 connector, powered at 8.2 VDC, for non-contact detection of metallic targets with a 40 mm or 50 mm sensing distance.
Supply voltage8.2 VDC
Switching frequency [F]100 Hz/100Hz
Repeat accuracy [R]≤ 3%
Dimensions40*80*104mm
MountingFlush/Nonflush
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
40*80*104mm
Supply voltage
8.2 VDC
Ambient Humidity
35...95%RH
Ambient temperature
-25°C...70°C
Assured distance [Sa]
0… 32mm/0… 40mm
Circuit protection
...
Connection Type
M12 connector
Degree of protection
IP67
Housing Material
PBT
Hysteresis range [%/Sr]
1...20%
Insulation Resistance
>50MΩ (500VDC)
Load Resistance
≥ 1K&Omega
Mounting
Flush/Nonflush
Output
NAMUR
Output Current
Triggered≤ 1mA,Not triggered≥ 2.2mA
Output Indicator
...
Rated distance [Sn]
40mm/50mm
Repeat accuracy [R]
≤ 3%
Standard target
Fe120*120*1t/Fe150*150*1t
Switch-point drifts [%/Sr]
≤ ±10%
Switching frequency [F]
100 Hz/100Hz
Vibration Resistance
10...50Hz(1.5mm)
Voltage Withstand
...
Integration
Points to check before using LE80XZ-E2-NAMUR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 8.2 VDC.
Power and communication
Supply voltage
8.2 VDC
Output Current
Triggered≤ 1mA,Not triggered≥ 2.2mA
Voltage Withstand
...
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 8.2 VDC.
Applications and use cases
Architectures in which LE80XZ-E2-NAMUR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of LE80XZ-E2-NAMUR can answer. A question is not asked when nothing is recorded to answer it.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details