Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.

LR12X-M – M12 analog output inductive sensor, 2 m PVC cable

M12 analog output inductive sensor, 2 m PVC cable

General Industrial Sensors & Transmitters

Manufacturer part number
LR12X-M
Manufacturer
Lanbao

M12 inductive sensor with analog current or voltage output, detecting metal targets at 2 mm flush or 4 mm non-flush sensing distance. Used for position and presence control in industrial environments.

Product overview

Overview. The Lanbao LR12X-M is an M12 inductive sensor with analog output, supplied with a 2 m PVC cable. It detects metal targets without contact and delivers a signal proportional to distance.

Main characteristics. The rated distance is 2 mm for flush mounting and 4 mm for non-flush mounting, with sensing ranges of 0.4 to 2 mm and 0.8 to 4 mm. Linearity is at most +5 %, repeat accuracy at most +3 % and switch-point drift at most +10 %/Sr. The switching frequency is 200 Hz flush and 100 Hz non-flush. The standard target is Fe 12×12×1 t. A yellow LED indicates the output state.

Outputs and connection. The sensor offers current, voltage or current plus voltage output. For voltage output the load must be at least 4.7 kΩ; for current output it must be at most 470 Ω. Connection is made by a 2 m PVC cable. Current consumption is at most 20 mA.

Power supply and environment. The supply voltage is 15 to 30 VDC, with reverse polarity protection. The housing is nickel-copper alloy and the degree of protection is IP67. The operating temperature range is -25 °C to 70 °C (minimum -20 °C), ambient humidity 35 to 95 %RH. Insulation resistance is at least 50 MΩ (500 VDC) and voltage withstand is 1000 VAC 50/60 Hz for 60 s. The sensor withstands vibration from 10 to 50 Hz (1.5 mm).

Dimensions and mounting. Dimensions are M12 × 61 mm and M12 × 65 mm. Mounting can be flush or non-flush.

Typical uses. This sensor suits presence and position detection of metal parts, and distance measurement where the PLC or acquisition system accepts an analog voltage or current signal.

Typical applications

Derived from the part category, not a compatibility statement.