MH40-MEASURING – RS485 Parallel Light Measuring Light Curtain

RS485 Parallel Light Measuring Light Curtain

General Industrial Sensors & Transmitters

  • RS-485
Manufacturer part number
MH40-MEASURING
Manufacturer
Lanbao

Lanbao MH40 measuring light curtain with 850 nm infrared parallel light, RS485 output and NPN/PNP switch outputs, for measuring and detecting opaque objects.

Product overview

Overview. The Lanbao MH40 measuring light curtain is a parallel-light photoelectric barrier manufactured by Shanghai Lanbao Sensor Technology Co., Ltd. It uses an 850 nm infrared light source and line synchronization. The MH40 series is offered in several detection heights, from 8 to 56 optical axes, with an optical axis distance of 40 mm.

Main characteristics. It detects an opaque object of Ø 60 mm over a detection distance of 0.5 to 5 m. Detection areas range from 280 mm to 2200 mm depending on the model. Response time is 5 ms to 24 ms depending on the configuration. Two mounting brackets are supplied, along with a 3 m 8-core shielded cable and a 15 m 4-core shielded cable.

Interfaces and connectivity. The emitter connects through an M12 4-pin connector with a 20 cm cable, the receiver through an M12 8-pin connector with a 20 cm cable. Output 1 is NPN/PNP with settable NO/NC logic, output 2 is RS485. Output indicators combine an OLED display and LED indicators.

Power and environment. The supply voltage is 15 to 30 VDC, with consumption below 130 mA for 16 axes at 30 VDC. Receiver load current is limited to 200 mA and voltage drop is below 1.5 V at 200 mA. The aluminium alloy housing has an IP65 protection rating. The operating temperature range is -25 °C to +55 °C and the ambient humidity range is 35% to 95% RH. Protection includes short-circuit protection, Zener protection, surge protection and reverse polarity protection.

Typical uses. With its RS485 output, the barrier can be connected to a PLC or a supervision system for object measurement and presence detection.

Integration. Impact resistance of 15 g, 16 ms, and vibration resistance from 10 to 55 Hz, amplitude 0.5 mm. Insulation resistance of at least 50 MΩ and impulse withstand voltage of 1000 V peak.

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote