PDT – Laser CCD diameter measuring linear position sensor
Laser CCD diameter measuring linear position sensor
- 10mm
- <150mA(Rated voltage)
- <0.5mA
- <120mA(Rated voltage)
- Manufacturer part number
- PDT_SERIES
- Manufacturer
- Lanbao
- Operating Temperature
- -10... +45°C(No freezing)
- Measuring Range
- 10mm
The Lanbao PDT-010M8 CCD laser sensor measures displacement and diameter over a 10 mm range, with a PDT-CT01 controller on DIN rail and RS485 communication.
- Operating Temperature-10... +45°C(No freezing)
- Measuring Range10mm
- Dynamic current<150mA(Rated voltage)
- Minimum (load) operating current<0.5mA
- Static Current<120mA(Rated voltage)
- Alarm lightRed LED(Receiver)
Product overview
Overview. The Lanbao PDT-010M8 linear position sensor, from the PDT series, is a CCD laser detection head used with the PDT-CT01 controller. It measures over a 10 mm range with a display resolution of 1 µm.
Main characteristics. Linearity is ±0.4 % F.S. (±40 µm) at a distance of 100 mm and repeatability is ±10 µm at 100 mm. The sampling period is 500 µs. The minimum detectable object is Φ 1 mm at a setting distance of 300 mm. A green LED assists optical axis calibration, with a dedicated alignment indication. The light source is a Class 1 red semiconductor laser.
Interfaces and connectivity. The controller and detection head communicate over an RS485 bus. The system supports one or two pairs, with multi-controller cascading and EtherCAT networking. An external input CH1 and a CH1 switching output, PNP/NPN optional, are provided, together with a CH1/CH2 analog output of 0 to 10 V with an output resistance of 100 Ω.
Power and environment. Power consumption is at most 720 mW at 24 VDC including emitter and receiver. Static current is below 120 mA and dynamic current below 150 mA at rated voltage. The detection head is metal and the controller plastic.
Typical uses. The sensor suits position and diameter control on automation lines, with measurements sent to a PLC over the RS485 bus or the analog output. The red alarm LED signals abnormal states.
Integration. The controller mounts on a DIN rail, and the CB-M2.6-YM8 connection cable links controller and head. Circuit protection includes overload indication, short-circuit protection and zener protection.
Highlights
- Alarm light: Red LED(Receiver)
- Ambient Humidity: 35...85% RH(No condensation)
- Anti-ambient Light: Incandescent light:<3,000lux
- Cable: PVC
- Circuit protection: Overload indication,short circuit protection,zener protection
- Communication function: Controller and detection head:RS485 bus
Good to know before integrating
- Thermal: rated operating range -10... +45°C(No freezing) — check it against the installation environment.
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for PDT_SERIES, with where it comes from. Use the filters to find one quickly.
All specifications (32)
| Characteristic | Value |
|---|---|
| Alarm light | Red LED(Receiver) |
| Ambient Humidity | 35...85% RH(No condensation) |
| Analog Output | CH1/CH2 output, analog voltage(0-10V output resistance 100Ω ) |
| Anti-ambient Light | Incandescent light:<3,000lux |
| Cable | PVC |
| Circuit protection | Overload indication,short circuit protection,zener protection |
| Communication function | Controller and detection head:RS485 bus |
| Connect cables | CB-M2.6-YM8 |
| Controller | PDT-CT01 |
| Detection head | PDT-010M8 |
| Display Resolution | 1μ m |
| Dynamic current | <150mA(Rated voltage) |
| External input | CH1 |
| Installation interval | 0...300mm |
| Installation Type | DIN Rail mounting setup |
| Light source | Red semiconductor laser Class 1 |
| Linearity | ±0.4%F.S.(±40μ m)at a distance of 100mm |
| Materials | Detection head:metal; Controller:plastic |
| Measuring Range | 10mm |
| Minimum detection object | Φ 1mm(Setting distance:300mm) |
| Minimum (load) operating current | <0.5mA |
| Number of connected units | 1/2 pairs |
| Operating Temperature | -10... +45°C(No freezing) |
| OPtical axis alignment indication | Yes |
| OPtical axis calibration light | Green LED(Including one Emitter and one receiver) |
| Power consumption | ≤ 720mW@24VDC(Including Emitter and receiver) |
| Protection degree | IP50 |
| Repeatability | ±10μ m(Setting distance:100 mm) |
| Sampling period | 500us |
| Static Current | <120mA(Rated voltage) |
| Switching output | CH1 output,PNP/NPN optional |
| Voltage drop | <2.5V@Ie=200mA |
No specification matches.
Last verification : 2026-11-03
Technical documentation
Official documents and the technical data recorded for PDT_SERIES. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
The Lanbao PDT-010M8 CCD laser sensor measures displacement and diameter over a 10 mm range, with a PDT-CT01 controller on DIN rail and RS485 communication.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Alarm light | Red LED(Receiver) |
| Ambient Humidity | 35...85% RH(No condensation) |
| Analog Output | CH1/CH2 output, analog voltage(0-10V output resistance 100Ω ) |
| Anti-ambient Light | Incandescent light:<3,000lux |
| Cable | PVC |
| Circuit protection | Overload indication,short circuit protection,zener protection |
| Communication function | Controller and detection head:RS485 bus |
| Connect cables | CB-M2.6-YM8 |
| Controller | PDT-CT01 |
| Detection head | PDT-010M8 |
| Display Resolution | 1μ m |
| Dynamic current | <150mA(Rated voltage) |
| External input | CH1 |
| Installation interval | 0...300mm |
| Installation Type | DIN Rail mounting setup |
| Light source | Red semiconductor laser Class 1 |
| Linearity | ±0.4%F.S.(±40μ m)at a distance of 100mm |
| Materials | Detection head:metal; Controller:plastic |
| Measuring Range | 10mm |
| Minimum detection object | Φ 1mm(Setting distance:300mm) |
| Minimum (load) operating current | <0.5mA |
| Number of connected units | 1/2 pairs |
| Operating Temperature | -10... +45°C(No freezing) |
| OPtical axis alignment indication | Yes |
| OPtical axis calibration light | Green LED(Including one Emitter and one receiver) |
| Power consumption | ≤ 720mW@24VDC(Including Emitter and receiver) |
| Protection degree | IP50 |
| Repeatability | ±10μ m(Setting distance:100 mm) |
| Sampling period | 500us |
| Static Current | <120mA(Rated voltage) |
| Switching output | CH1 output,PNP/NPN optional |
| Voltage drop | <2.5V@Ie=200mA |
Integration
Points to check before using PDT_SERIES in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
Power and communication
| Dynamic current | <150mA(Rated voltage) |
| Minimum (load) operating current | <0.5mA |
| Power consumption | ≤ 720mW@24VDC(Including Emitter and receiver) |
| Static Current | <120mA(Rated voltage) |
| Voltage drop | <2.5V@Ie=200mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
- Thermal : rated operating range -10... +45°C(No freezing) — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of PDT_SERIES can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication function": Controller and detection head:RS485 bus.
2What is the operating temperature range?
-10... +45°C(No freezing) (source: Operating Temperature).
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | PDT_SERIES |
| Manufacturer | Lanbao |