Overview. The Lanbao PST-TC50-V is a miniature photoelectric sensor with a 680 nm red Vcsel light source, supplied with two M3×16 mm screws, two nuts and its operation manual. It is designed to detect opaque objects in automation systems.
Main characteristics. Sensing distance of 50 cm, spot size of 4 mm at 50 cm, minimum target diameter of 2 mm for opaque objects, response times T-on and T-off below 0.5 ms. PMMA lens and ABS housing.
Interfaces and connection. PNP or NPN outputs, normally open (NO) or normally closed (NC) operation. Load current up to 50 mA, voltage drop of 1.5 V maximum. Connection by 2 m PVC cable or by 3-pin M8 connector on a 20 cm PVC cable. Green indicator for power supply and stability, yellow indicator for output.
Power and environment. Supply voltage of 10 to 30 VDC. Consumption of 5 mA maximum for the emitter and 15 mA maximum for the receiver. Protection against short circuit, reverse polarity and overload. IP65 protection rating, operating temperature from -10 to 45 °C, storage temperature from -20 to 85 °C, without condensation or icing. Ambient light immunity up to 10,000 lux for sunlight and 3,000 lux for incandescent light.
Integration. Connects to a PLC or control system through the selected PNP or NPN output. Available on quotation from Atlas Electronics.
PNP — NO — PST-TC50DV — PST-TC50DPOR — PST-TC50DV-F3
PST-TC50DPOR -F3
Protection circuit
Short circuit,reverse polarity,overload protection
Protection degree
IP65
Sensing Distance
50cm
Shell material
ABS
Spot Size
4mm@50cm
Storage Temperature
-20...85 º C(No condensation、No icing)
Voltage drop
≤ 1.5V
Integration
Points to check before using PST-TC50-V in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 10...30VDC.
Power and communication
Supply voltage
10...30VDC
Consumption Current
Emitter:≤ 5mA; Receiver:≤ 15mA
Load Current
≤ 50mA
Voltage drop
≤ 1.5V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 10...30VDC.
Applications and use cases
Architectures in which PST-TC50-V can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details