4-20MA
Liquid ultrasonic flow meter clamp on flow meter data logger RS485 modbus

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std:10m
Liquid ultrasonic flow meter clamp on flow meter data logger RS485 modbus
Lanry 4-20mA, listed under “Ultrasonic Flow Meters”.
liquid ultrasonic flow meter clamp on flow meter data logger 4-20mA RS485 modbus
Short Description:
TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Send email to us
Description
Features
Specificaitons
Configuration Code
Applications
TF1100 -EC Wall-mounted Transit Time Ultrasonic Flow meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Features
Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt.
Wide liquid temperature range: -35℃~200℃.
Data logger function.
Thermal energy measurement capability can be optional.
For commonly used pipe materials and diameters from 20mm to over 6000m.
Wide bi-directional flow range of 0.01 m/s to 12 m/s.
Specificaitons
Transmitter:
Transducer:
Configuration Code
Applications
● Service and maintenance
● Replacement of defective devices
● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves
● Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
● Petrochemical industry
● Chemical industry -chlorine, alcohol, acids,.thermal oils.etc
● Refrigeration and air conditioning systems
● Food, beverage and pharmaceutical industry
● Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
● Metallurgy and mining applications
● Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
Previous: transit time liquid ultrasonic flow meter clamp on flow meter data storage and pulse output
Next: LMU Serials Compact Type Ultrasonic Level Meter
Transit Time Flow Measurement
Transit Time Flow Meter
Transit Time Ultrasonic Flow Meter
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 4-20MA, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | LMU Serials Compact Type Ultrasonic Level Meter |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | transit time liquid ultrasonic flow meter clamp on flow meter data storage and pulse output |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for 4-20MA. For a missing document or a specific revision, our experts send it to you.
Lanry 4-20mA, listed under “Ultrasonic Flow Meters”.
| Parameter | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | LMU Serials Compact Type Ultrasonic Level Meter |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | transit time liquid ultrasonic flow meter clamp on flow meter data storage and pulse output |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
Points to check before using 4-20MA in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 4-20MA can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Liquid ultrasonic flow meter clamp on flow meter data logger RS485 modbus

Portable Ultrasonic Flow Meter price handheld Flowmeter handheld Ultrasonic FlowMeters

Output Portable Handheld Liquid Ultrasonic Flow Meter

Insertion Doppler Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 4-20MA |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details