Portable clamp-on ultrasonic flowmeter measuring the flow of liquids and liquefied gases in fully filled pipes without intrusion. Suited to service, maintenance and temporary meter replacement.
Operating Temperature-20℃ to +60℃
Flow velocity range0.01 to 12 m/s, bi-directional
Response time0.5s
Cable LengthStd:5m
Damping of displayed value0-99s(selectable by user)
Degree of protectionIP65
Product overview
Overview. The Lanry bidirectional portable transit-time ultrasonic flowmeter data logger measures the flow of liquids and liquefied gases in fully filled pipes, using clamp-on ultrasonic transducers mounted on the external surface of the pipe for non-invasive, non-intrusive measurement.
Main characteristics. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. The bidirectional flow range is 0.01 m/s to 12 m/s and the liquid temperature range is -35 ℃ to 200 ℃. The meter works reliably in clean and somewhat dirty liquids with turbidity below 10000 ppm. It features a back-lit 4-line display in a rugged, watertight enclosure.
Power and data logging. A rechargeable battery provides 50 hours of operation. The integrated data logger function stores measurements for later analysis.
Thermal energy measurement. With paired temperature sensors, the optional heat measurement function enables analysis of thermal energy usage in a facility.
Typical uses. This lightweight meter, easily transported in a box, suits service and maintenance activities, control of permanently installed meters, and their temporary replacement.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for BIDIRECTIONAL-PORTABLE-TRANSIT-TIME-ULTRASONIC-FLOWMETER-DATA-LOGGER, with where it comes from. Use the filters to find one quickly.
All specifications (29)
Characteristic
Value
Response time
0.5s
Accuracy
±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s
Cable Length
Std:5m
Communication
4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS
Damping of displayed value
0-99s(selectable by user)
Degree of protection
IP65
Display
4 line×16 English letters LCD graphic display, backlit
Enclosure Type
Portable
Flow velocity range
0.01 to 12 m/s, bi-directional
Housing Material
ABS( UL 94HB)
Liquid Types Supported
both clean and somewhat dirty liquids with turbidity <10000 ppm
Material of transducer
Aluminum for standard temp. sensor,and peek for high temp. sensor
20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Power supply
AC: 85-265V Up to 50 hours with fully charged internal batteries
Rate
Rate and Velocity Display
Repeatability
0.2% of reading
Resolution
0.25mm/s
Security
Keypad lockout, system lockout
Sensitivity
0.003m/s
Size
270X215X175mm
Suited Liquid Temperature
Std. Temp.: -35℃~85℃ for short periods up to 120℃
Temperature sensor
Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%
Thermal energy
unit GJ,KWh can be optional
Totalized
gallons, ft³, barrels, lbs, liters, m³,kg
Transducer Size
Type S 48 (h)*28(w)*2 8 (d)mm
Units
User Configured (English and Metric)
Weight
3kg
No specification matches.
Last verification : 2026-11-03
Integration
Points to check before using BIDIRECTIONAL-PORTABLE-TRANSIT-TIME-ULTRASONIC-FLOWMETER-DATA-LOGGER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ to +60℃ — check it against the installation environment.
Power and communication
Power supply
AC: 85-265V Up to 50 hours with fully charged internal batteries
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ to +60℃ — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of BIDIRECTIONAL-PORTABLE-TRANSIT-TIME-ULTRASONIC-FLOWMETER-DATA-LOGGER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication": 4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS.
2Does it support RS-232?
Yes — recorded under "Communication": 4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS.
3Does it support CAN bus?
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
4Does it support Modbus?
Yes — recorded under "Communication": 4~20mA,OCT,RS232, RS485 (Modbus),Data Logged,GPRS.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details