TF1100-EI – Insertion ultrasonic flow meter, transit-time measurement

Insertion ultrasonic flow meter, transit-time measurement

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • DN65-6000
  • 0.5s
  • Std:10m
Manufacturer part number
DATA-LOGGER-WALL-MOUNTED-INSERTION-ULTRASONIC-FLOW-METER
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Pipe diameter range
DN65-6000

Insertion ultrasonic flow meter using transit-time measurement, hot-tapped on pipes from DN65 to DN6000 to measure liquid flow without pressure drop.

Product overview

Overview. The Lanry TF1100-EI insertion ultrasonic flow meter is a transit-time ultrasonic flow meter for measuring liquid flow from outside the pipe. It relies on transit-time difference correlation and digital signal processing.

Main characteristics. Measurable flow velocity from 0.01 to 12 m/s, bi-directional, for pipe diameters from DN65 to DN6000. Accuracy is ±1.0% of reading above 0.3 m/s and ±0.003 m/s of reading below it, with repeatability of 0.2% of reading and resolution of 0.25 mm/s. Display damping is user-selectable from 0 to 99 s. The Pt1000 temperature sensor covers 0 to 200 °C.

Installation. The stainless steel type S transducer is installed hot-tapped without interrupting the pipeline. It has no moving parts and causes no pressure drop. The fiberglass wall-mounted enclosure, rated IP66 according to EN60529, measures 244 × 196 × 114 mm and weighs 2.4 kg, with a standard 10 m cable.

Interfaces and connectivity. 4 to 20 mA outputs (accuracy 0.1%), OCT pulse, relay, RS232, RS485 with Modbus protocol and data logger function. A 4-line by 16-character backlit graphic LCD displays flow rate, velocity and totalizers, in user-configured English or metric units.

Power and environment. Power supply 85 to 265 V AC or 24 V DC, 500 mA. Operating temperature -20 °C to +60 °C, liquid temperature -35 °C to 85 °C for the standard model. Keypad and system lockout secure the configuration.

Typical uses. Flow measurement of clean or somewhat dirty liquids with turbidity below 10,000 ppm. The RS485 Modbus output allows connection to a PLC or supervisory system. Totalizers and the thermal energy calculation, with paired temperature sensors, complete the measurement.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters
Request a quote