DF6100-EP
Portable Doppler Clamp-On Ultrasonic Flowmeter

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.05- 12 m/s
- Pipe diameter range
- 40- 4 000 mm
- Accuracy
- 0.5% -- 2.0% F.S.
Portable Doppler Clamp-On Ultrasonic Flowmeter
Portable Doppler ultrasonic flowmeter with clamp-on transducers for measuring volumetric flow of liquids in full closed conduits containing air bubbles or suspended solids.
Overview. The Lanry DF6100-EP portable Doppler ultrasonic flowmeter measures volumetric flow within a closed conduit. The pipe must be full of liquid and contain a certain amount of air bubbles or suspended solids. The instrument displays flow rate and flow totalizer.
Main characteristics. Flow velocity range of 0.05 to 12 m/s, for pipe diameters from 40 to 4 000 mm. Accuracy of 0.5% to 2.0% of full scale, repeatability of 0.5% of reading, resolution of 0.25 mm/s. Response time of 2 to 60 s as an option. Clamp-on transducers measuring 60 x 34 x 32 mm, with no need to shut down the pipe flow during installation.
Interfaces and connectivity. 4-20 mA and OCT outputs. 2-line by 8-character LCD display, with 8-digit rate or 8-digit resettable total. 6-button keypad. Units configurable in English and Metric, totalized in gallons, ft³, barrels, lbs, liters, m³ and kg.
Power and environment. AC power supply 85-265 V, up to 50 hours of operation with fully charged internal batteries. Degree of protection IP65 according to EN60529. Operating temperature of -20 °C to +60 °C, minimum operating temperature of -30 °C. Aluminum transducers for standard temperature, PEEK for high temperature, suited to liquids up to 120 °C for short periods. ABS housing, transmitter of 270 x 125 x 175 mm weighing 3 kg, standard cable length of 5 m.
Typical uses. Portable flow checking on pipes in service, for liquids containing at least 100 ppm of reflectors, of which at least 20% are larger than 100 micron.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DF6100-EP, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 2-60s for optional |
| Accuracy | 0.5% -- 2.0% F.S. |
| Cable Length | Std: 5m |
| Communication | 4-20mA OCT output |
| Degree of protection | IP65 according to EN60529 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Enclosure Type | Portable |
| Flow velocity range | 0.05- 12 m/s |
| Housing Material | ABS |
| Keypad | 6 pcs buttons |
| Liquid Types Supported | Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Material of transducer | Aluminum (standard temperature). sensor, Peek (high temperature) |
| Measurement Principle | Doppler ultrasonic |
| Next | Transit-Time Multi-channel Insertion Ultrasonic Flowmeter TF1100-MI |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 40- 4 000 mm |
| Power supply | AC: 85-265V Up to 50 hours with fully charged internal batteries |
| Previous | Handheld Doppler Ultrasonic Flowmeter DF6100-EH |
| Rate | Rate and Velocity Display |
| Repeatability | 0.5% of reading |
| Resolution | 0.25mm/s |
| Size | Transmitter:270X125X175mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | 60(h)*34(w)*32(d)mm |
| Transducers Type | Clamp-on |
| Units | User Configured (English and Metric) |
| Weight | 3kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DF6100-EP. For a missing document or a specific revision, our experts send it to you.
Portable Doppler ultrasonic flowmeter with clamp-on transducers for measuring volumetric flow of liquids in full closed conduits containing air bubbles or suspended solids.
| Parameter | Value |
|---|---|
| Response time | 2-60s for optional |
| Accuracy | 0.5% -- 2.0% F.S. |
| Cable Length | Std: 5m |
| Communication | 4-20mA OCT output |
| Degree of protection | IP65 according to EN60529 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Enclosure Type | Portable |
| Flow velocity range | 0.05- 12 m/s |
| Housing Material | ABS |
| Keypad | 6 pcs buttons |
| Liquid Types Supported | Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Material of transducer | Aluminum (standard temperature). sensor, Peek (high temperature) |
| Measurement Principle | Doppler ultrasonic |
| Next | Transit-Time Multi-channel Insertion Ultrasonic Flowmeter TF1100-MI |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 40- 4 000 mm |
| Power supply | AC: 85-265V Up to 50 hours with fully charged internal batteries |
| Previous | Handheld Doppler Ultrasonic Flowmeter DF6100-EH |
| Rate | Rate and Velocity Display |
| Repeatability | 0.5% of reading |
| Resolution | 0.25mm/s |
| Size | Transmitter:270X125X175mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | 60(h)*34(w)*32(d)mm |
| Transducers Type | Clamp-on |
| Units | User Configured (English and Metric) |
| Weight | 3kg |
Points to check before using DF6100-EP in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V Up to 50 hours with fully charged internal batteries |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DF6100-EP can answer. A question is not asked when nothing is recorded to answer it.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Portable Doppler Clamp-On Ultrasonic Flowmeter

Handheld Doppler Ultrasonic Flowmeter

Doppler Flow Meter

Insertion Doppler Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DF6100-EP |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details