DN150
Partially filled pipe Doppler ultrasonic flow meter

- Environmental — Operating Temperature
- 0°C 〜+60°C water temperature
- Operating Temperature
- 0°C ~+60°C
- Temperature range
- 0°C to 60°C
- Depth (Pressure) — Range:
- 0mm to 10000mm (10m)
Partially filled pipe Doppler ultrasonic flow meter
Doppler ultrasonic flow meter for partially filled pipes DN150 and above, open channels and rivers, measuring water velocity, depth and conductivity.
Overview. The Lanry DN150 is a Doppler ultrasonic flow meter for partially filled pipes DN150 and above. It measures the velocity, depth and conductivity of water flowing in rivers, streams, open channels and pipes. With the companion DOF6000 calculator, flow rate and total flow can also be calculated.
Main characteristics. Velocity is measured with the ultrasonic Doppler principle in quadrature sampling mode, with a range of 20 mm/s to 13.2 m/s depending on the version and an accuracy of ±1 % R, with bidirectional measurement. Depth is measured by two sensors: pressure, from 0 to 10,000 mm with an accuracy of ±2 mm, and ultrasonic, from 20 mm to 5,000 mm with an accuracy of ±1 mm. Electrical conductivity is measured from 0 to 200,000 µS/cm with an accuracy of ±1 % R. The calculator can determine the cross-sectional area of a partially filled pipe or a river from up to 20 coordinate points describing its shape.
Interfaces and connectivity. Pulse, 4-20 mA (flow and depth), RS485/Modbus RTU with up to 500 m of cable, SDI-12 with up to 50 m of cable, datalogger and GPRS outputs. The sensor includes 16 GB of data storage.
Power and environment. Calculator powered by 220 VAC and 12-24 VDC, sensor powered by 12 VDC. IP68 protection, operating temperature from 0 °C to +60 °C and storage temperature from -20 °C to +60 °C.
Typical uses. Measurement in wastewater, lightly dirty liquids, rainwater, river water, canals, streams and culverts, for partially filled pipes and open channels.
Integration. The RS485 output with Modbus RTU allows connection to a PLC or a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DN150, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | Fiber Glass |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 2mm |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1mm |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5" color LCD |
| Electrical Conductivity (EC) | Recorded as a 16-bit value (0 to 65,535 µS/cm) or a 32-bit value (0 to 262,143 µS/cm) |
| Electrical Conductivity (EC) — Accuracy | ±1% R |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 µS/cm, Typically ± 1% of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Next | partially filled pipe doppler ultrasonic flow meter for wastewater |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 220VAC& 12-24VDC; Sensor:12VDC |
| Previous | RS485 modbus open channel and river measurement area velocity doppler flow meter monitor |
| Size | 244L×196W×114H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Wall-mounted |
| Velocity — Velocity accuracy: | ±1 % R |
| Velocity — Velocity range: | 20mm/s-0.8m/s; 20mm/s-1.6m/s; 20mm/s-3.2m/s (default); 20mm/s- 6.4m/s; 20mm/s-13.2m/s; Bidirectional velocity capability |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DN150. For a missing document or a specific revision, our experts send it to you.
Doppler ultrasonic flow meter for partially filled pipes DN150 and above, open channels and rivers, measuring water velocity, depth and conductivity.
| Parameter | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | Fiber Glass |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 2mm |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1mm |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5" color LCD |
| Electrical Conductivity (EC) | Recorded as a 16-bit value (0 to 65,535 µS/cm) or a 32-bit value (0 to 262,143 µS/cm) |
| Electrical Conductivity (EC) — Accuracy | ±1% R |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 µS/cm, Typically ± 1% of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Next | partially filled pipe doppler ultrasonic flow meter for wastewater |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 220VAC& 12-24VDC; Sensor:12VDC |
| Previous | RS485 modbus open channel and river measurement area velocity doppler flow meter monitor |
| Size | 244L×196W×114H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Wall-mounted |
| Velocity — Velocity accuracy: | ±1 % R |
| Velocity — Velocity range: | 20mm/s-0.8m/s; 20mm/s-1.6m/s; 20mm/s-3.2m/s (default); 20mm/s- 6.4m/s; 20mm/s-13.2m/s; Bidirectional velocity capability |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 2.4kg |
Points to check before using DN150 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | Calculator: 220VAC& 12-24VDC; Sensor:12VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DN150 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output": Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS.
Yes — recorded under "Output": Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS.
0°C 〜+60°C water temperature (source: Environmental — Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Partially filled pipe Doppler ultrasonic flow meter

Area Velocity Flow Meter

Ultrasonic Flow

Agriculture Irrigation Flow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN150 |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details