DN20-DN6000
Wall-mount clamp-on transit-time ultrasonic flow meter

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std:10m
Wall-mount clamp-on transit-time ultrasonic flow meter
Clamp-on transit-time ultrasonic flow meter for measuring liquid flow in a fully filled pipe without cutting the pipe. Used for maintenance, control and temporary replacement of permanently installed meters.
Overview. The Lanry TF1100-EC is a wall-mount transit-time ultrasonic flow meter. Its clamp-on transducers are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquids and liquefied gases in fully filled pipes.
Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional. Accuracy of ±1.0% of reading above 0.3 m/s and ±0.003 m/s below. Repeatability of 0.2% of reading. Pipe diameters from 20 to 6000 mm depending on transducer type S, M or L. Flow rate and velocity display, totalisation in gallons, ft³, barrels, lbs, liters, m³ and kg, units user-configurable in English and Metric. Data logger function and optional thermal energy measurement in GJ or kWh.
Interfaces and connectivity. 4~20 mA, relay, RS232 and RS485 outputs with Modbus protocol. Temperature measured by a clamp-on Pt1000 sensor, accuracy ±0.1%.
Power and environment. Power supply 85-265 V AC or 24 V DC, 500 mA. Fiberglass housing, IP66 degree of protection according to EN60529. Operating temperature -20 °C to +60 °C, liquid temperature -35 °C to 85 °C for short periods up to 120 °C. Dimensions 244 × 196 × 114 mm, weight 2.4 kg. Backlit 4-line × 16-character graphic LCD display, keypad lockout.
Typical uses. Service and maintenance, performance checks of pumps and regulating valves, temporary replacement of permanently installed meters, in water networks, chemical and petrochemical industry, air conditioning and power generation.
Integration. The RS485 signal with Modbus protocol allows connection to a programmable logic controller or a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DN20-DN6000, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Analog 4~20mA Flowmeter DN50-700 Digital RS485 Clamp on Ultrasonic Water Liquid Flow Meter Sensor |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Price Wall Mounted Ultrasonic Water Flowmeter Clamp On Ultrasonic Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DN20-DN6000. For a missing document or a specific revision, our experts send it to you.
Clamp-on transit-time ultrasonic flow meter for measuring liquid flow in a fully filled pipe without cutting the pipe. Used for maintenance, control and temporary replacement of permanently installed meters.
| Parameter | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Analog 4~20mA Flowmeter DN50-700 Digital RS485 Clamp on Ultrasonic Water Liquid Flow Meter Sensor |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Price Wall Mounted Ultrasonic Water Flowmeter Clamp On Ultrasonic Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
Points to check before using DN20-DN6000 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DN20-DN6000 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Wall-mount clamp-on transit-time ultrasonic flow meter

Portable Ultrasonic Flow Meter price handheld Flowmeter handheld Ultrasonic FlowMeters

Output Portable Handheld Liquid Ultrasonic Flow Meter

Insertion Doppler Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN20-DN6000 |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details