TF1100-CH – Portable clamp-on ultrasonic flow meter, transit-time measurement

Portable clamp-on ultrasonic flow meter, transit-time measurement

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • 0.5s
  • Std: 5m
  • OCT, RS232,Logged data
Manufacturer part number
DN40-DN5000MM
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Response time
0.5s

Portable ultrasonic flow meter with clamp-on transducers, measuring liquid flow in full pipes without cutting into the piping. Suited to maintenance work and spot checks.

Product overview

Overview. The Lanry TF1100-CH portable ultrasonic flow meter, also listed as Dn40-Dn5000mm, is an ultrasonic flow meter working on the transit-time difference correlation principle. The transducers are mounted on the external surface of the pipe for non-invasive, non-intrusive measurement of liquids and liquefied gases in fully filled pipes.

Main characteristics. Bidirectional flow velocity range of 0.01 to 12 m/s. Accuracy of ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s. Repeatability of 0.2% of reading, resolution of 0.25 mm/s and response time of 0.5 s. Displayed value damping adjustable from 0 to 99 s.

Display and data. 4-line by 16-character backlit graphic LCD showing rate and velocity. Data logger function. Totalisation in gallons, ft³, barrels, lbs, liters, m³ and kg, with user-configured English or metric units.

Transducers and pipe sizes. Three transducer pairs cover pipe diameter ranges of 20 to 50 mm (type S), 40 to 1000 mm (type M) and 1000 to 6000 mm (type L). Aluminum transducers for the standard temperature sensor and PEEK for the high temperature sensor. Supports clean and somewhat dirty liquids with turbidity below 10000 ppm. Standard cable length 5 m.

Power and environment. AC 85 to 265 V supply, up to 14 h operation with fully charged internal batteries. Degree of protection IP65 according to EN60529. Operating temperature -20 °C to +60 °C, minimum operating temperature -30 °C, suited liquid temperature -35 °C to 85 °C, up to 120 °C for short periods with the standard sensor. ABS housing (UL 94HB), dimensions 212 × 100 × 36 mm, weight 0.5 kg.

Typical uses. Mobile measurement, flow rate calibration, comparison of data, checking the running status of installed meters, or temporary replacement of a permanently installed meter.

Security. Keypad lockout and system lockout.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std: 5m
  • Communication: OCT, RS232,Logged data
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP65 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.