DN40-DN5000MM
Portable clamp-on ultrasonic flow meter, transit-time measurement

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std: 5m
Portable clamp-on ultrasonic flow meter, transit-time measurement
Portable ultrasonic flow meter with clamp-on transducers, measuring liquid flow in full pipes without cutting into the piping. Suited to maintenance work and spot checks.
Overview. The Lanry TF1100-CH portable ultrasonic flow meter, also listed as Dn40-Dn5000mm, is an ultrasonic flow meter working on the transit-time difference correlation principle. The transducers are mounted on the external surface of the pipe for non-invasive, non-intrusive measurement of liquids and liquefied gases in fully filled pipes.
Main characteristics. Bidirectional flow velocity range of 0.01 to 12 m/s. Accuracy of ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s. Repeatability of 0.2% of reading, resolution of 0.25 mm/s and response time of 0.5 s. Displayed value damping adjustable from 0 to 99 s.
Display and data. 4-line by 16-character backlit graphic LCD showing rate and velocity. Data logger function. Totalisation in gallons, ft³, barrels, lbs, liters, m³ and kg, with user-configured English or metric units.
Transducers and pipe sizes. Three transducer pairs cover pipe diameter ranges of 20 to 50 mm (type S), 40 to 1000 mm (type M) and 1000 to 6000 mm (type L). Aluminum transducers for the standard temperature sensor and PEEK for the high temperature sensor. Supports clean and somewhat dirty liquids with turbidity below 10000 ppm. Standard cable length 5 m.
Power and environment. AC 85 to 265 V supply, up to 14 h operation with fully charged internal batteries. Degree of protection IP65 according to EN60529. Operating temperature -20 °C to +60 °C, minimum operating temperature -30 °C, suited liquid temperature -35 °C to 85 °C, up to 120 °C for short periods with the standard sensor. ABS housing (UL 94HB), dimensions 212 × 100 × 36 mm, weight 0.5 kg.
Typical uses. Mobile measurement, flow rate calibration, comparison of data, checking the running status of installed meters, or temporary replacement of a permanently installed meter.
Security. Keypad lockout and system lockout.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DN40-DN5000MM, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std: 5m |
| Communication | OCT, RS232,Logged data |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP65 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Handheld |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | ABS( UL 94HB) |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum for standard temp. s ensor, and peek for high temp. sensor |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
| Previous | Handheld Ultrasonic Flowmeter Portable Water Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 212*100*36mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 0.5kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DN40-DN5000MM. For a missing document or a specific revision, our experts send it to you.
Portable ultrasonic flow meter with clamp-on transducers, measuring liquid flow in full pipes without cutting into the piping. Suited to maintenance work and spot checks.
| Parameter | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std: 5m |
| Communication | OCT, RS232,Logged data |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP65 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Handheld |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | ABS( UL 94HB) |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum for standard temp. s ensor, and peek for high temp. sensor |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
| Previous | Handheld Ultrasonic Flowmeter Portable Water Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 212*100*36mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 0.5kg |
Points to check before using DN40-DN5000MM in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DN40-DN5000MM can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": OCT, RS232,Logged data.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Portable clamp-on ultrasonic flow meter, transit-time measurement

Portable Ultrasonic Flow Meter price handheld Flowmeter handheld Ultrasonic FlowMeters

Output Portable Handheld Liquid Ultrasonic Flow Meter

Doppler Flow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN40-DN5000MM |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details