DN50
Clamp-on ultrasonic Doppler flowmeter

Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.
Clamp-on ultrasonic Doppler flowmeter
Wall-mounted clamp-on Doppler ultrasonic flowmeter measuring the volumetric flow of liquids in a full closed conduit, with 4-20mA, relay and OCT outputs.
Overview. The Lanry DF6100-EC is a wall-mounted Doppler ultrasonic flowmeter designed to measure the volumetric flow of liquid in a closed conduit that is full of liquid. The liquid must contain a certain amount of air bubbles or suspended solids.
Main characteristics. It suits pipe diameters from 40 to 4 000 mm, with a flow velocity range of 0.05 to 12 m/s and a repeatability of 0.2% of reading. Accuracy is stated from 0.5% to 2.0% F.S., and resolution is 0.25 mm/s. The 2 line × 8 character LCD displays rate and totalizer, with 4 keypad buttons and user-configured units in English or metric.
Interfaces and connectivity. The transmitter provides 4-20 mA, relay and OCT outputs. The clamp-on transducers mount on the pipe without shutting down the flow. The standard cable length is 10 m.
Power and environment. Power supply AC 85-265 V or DC 24 V/500 mA. Degree of protection IP66 according to EN60529, fibreglass housing for wall mounting, operating temperature -20 °C to +60 °C. Aluminium transducers suit liquids from -35 °C to 85 °C, with a PEEK transducer available for high temperature.
Typical uses. Flow measurement of liquids in full pipes, including sewage and waste water as stated by the manufacturer.
Installation. Sufficient straight pipe is needed upstream of the transducers. Clamp-on mounting suits pipe materials with good acoustical conductivity; for underground installation the manufacturer recommends the insertion type.
No published question about this part yet. Questions are reviewed before publication.
Official documents and the technical data recorded for DN50. For a missing document or a specific revision, our experts send it to you.
Wall-mounted clamp-on Doppler ultrasonic flowmeter measuring the volumetric flow of liquids in a full closed conduit, with 4-20mA, relay and OCT outputs.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Clamp-on ultrasonic Doppler flowmeter

Area Velocity Flow Meter

Ultrasonic Flow

Agriculture Irrigation Flow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN50 |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details