DN50-700
Clamp-on ultrasonic flow meter, 4-20 mA and RS485 output

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std:10m
Clamp-on ultrasonic flow meter, 4-20 mA and RS485 output
Ultrasonic flow meter mounted on the outside of the pipe, with no cutting or process interruption, for measuring liquid flow in fully filled pipes. Suited to maintenance, control and temporary replacement of meters.
Lanry TF1100-EC, clamp-on transit-time ultrasonic flow meter (wall-mounted) for measuring the flow of liquids and liquefied gases in fully filled pipes. The transducers are mounted on the external surface of the pipe, with no cutting and no process interruption.
Measurement principle and range. The measurement is based on the transit-time method and the ultrasonic transit-time difference correlation principle. The flow velocity range is 0.01 to 12 m/s, bi-directional. Pipe diameters covered are 20-50 mm for type S, 40-1000 mm for type M and 1000-6000 mm for type L. Accuracy is ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s, with repeatability of 0.2% of reading.
Connectivity and outputs. The transmitter provides an analog 4-20 mA output (accuracy 0.1%), RS232 and RS485 ports with Modbus protocol, a relay and a data logger function. Totalized quantities are available in gallons, ft³, barrels, lbs, liters, m³ and kg, and thermal energy measurement in GJ or kWh is available as an option with a Pt1000 temperature sensor.
Power, environment and construction. The transmitter is powered by 85-265 V AC or 24 V DC / 500 mA. It has an IP66 degree of protection according to EN60529 and an operating temperature range of -20 °C to +60 °C. Admitted liquids are clean or somewhat dirty, with turbidity below 10000 ppm, and the liquid temperature can reach 85 °C continuously and 120 °C for short periods. The housing is fiberglass and the transducers are aluminum, or PEEK for high temperatures. Weight is 2.4 kg.
Typical uses. Service and replacement of defective meters, pump performance measurement, monitoring of regulating valves, flow measurement in water, waste water, cooling water or sea water.
Integration. Thanks to its RS485 Modbus port, the device can be connected to a PLC or a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DN50-700, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Digital Wall Mounted Clamp on Ultrasonic Flowmeter Flow Meter |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Wallmount Ultrasonic Flow Meter Clamp On Flow Meter DN20-DN6000 Ultrasonic Flowmeter Liquid Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DN50-700. For a missing document or a specific revision, our experts send it to you.
Ultrasonic flow meter mounted on the outside of the pipe, with no cutting or process interruption, for measuring liquid flow in fully filled pipes. Suited to maintenance, control and temporary replacement of meters.
| Parameter | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Digital Wall Mounted Clamp on Ultrasonic Flowmeter Flow Meter |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Wallmount Ultrasonic Flow Meter Clamp On Flow Meter DN20-DN6000 Ultrasonic Flowmeter Liquid Flow Meter |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
Points to check before using DN50-700 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DN50-700 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Clamp-on ultrasonic flow meter, 4-20 mA and RS485 output

bidirectional ultrasonic open channel flow sensor

Ultrasonic Sensor ango Sense CS100

Keepa - Social Distance Habit Trainer / Social Distancing Wristband for Children, Bulit-in ultrasonic sensor, 3 Alert Modes, Switchable Alert Distance

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN50-700 |
| Manufacturer | Lanry |
Ultrasonic Sensors
Ultrasonic distance sensor module for WisBlock · Ref. : 100042
Price on request
Ultrasonic Sensors
IP67 waterproof transceiver ultrasonic distance sensor · Ref. : DYP-A06
Price on request
Ultrasonic Sensors
Ultrasonic distance sensor 300 to 5000 mm, multiple outputs · Ref. : SEN0269
Price on request
Ultrasonic Sensors
Automotive ultrasonic sensor for reversing radar · Ref. : TK0158
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details