TF1100-EI – Insertion ultrasonic flow meter, 4-20 mA output, wall-mounted

Insertion ultrasonic flow meter, 4-20 mA output, wall-mounted

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • DN65-6000
  • 0.5s
  • Std:10m
Manufacturer part number
DN65
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Pipe diameter range
DN65-6000

Transit-time insertion ultrasonic flow meter for measuring liquid flow in clean or slightly dirty liquids, with 4-20 mA output, relay outputs and RS232 and RS485 Modbus links.

Product overview

Overview. The Lanry TF1100-EI is a transit-time insertion ultrasonic flow meter for accurate liquid flow measurement from outside a pipe. The transducers are mounted hot-tapped, without interrupting the line, and do not intrude into the flow, so they generate no disturbance or pressure drop.

Measurement and accuracy. The principle is ultrasonic transit-time difference correlation. The measurable flow velocity ranges from 0.01 to 12 m/s, bi-directional. Accuracy is ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below, with repeatability of 0.2% of reading and resolution of 0.25 mm/s. The Pt1000 temperature sensor (0 to 200 °C, accuracy ±0.1%) enables thermal energy measurement, in GJ or kWh as an option.

Interfaces and connectivity. 4-20 mA output (accuracy 0.1%), relay outputs, RS232 and RS485 links with Modbus protocol, and a data logger function. The display is a 4-line by 16-character backlit graphic LCD showing flow and velocity, with totalizers in multiple units and units configurable in English or metric.

Power and environment. Power supply 85-265 V AC or 24 V DC / 500 mA. Fiberglass wall-mounted enclosure, IP66 protection according to EN60529. Operating temperature -20 °C to +60 °C, liquid temperature -35 °C to 85 °C. Stainless steel transducer, size Φ58 × 199 mm, 10 m standard cable, weight 2.4 kg.

Typical uses. Suited to full pipes from DN65 to DN6000 and to liquids with turbidity below 10,000 ppm. Modbus RS485 allows connection to a PLC or a supervision system.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.