TF1100-EI – Transit-time ultrasonic flow meter, stainless insertion, hot water

Transit-time ultrasonic flow meter, stainless insertion, hot water

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • DN65-6000
  • 0.5s
  • Std:10m
Manufacturer part number
DN65-DN6000
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Pipe diameter range
DN65-6000

Transit-time ultrasonic flow meter with stainless steel insertion transducers for measuring clean or slightly dirty liquid flow in pipes from DN65 to DN6000.

Product overview

Overview. The Lanry TF1100-EI is a transit-time ultrasonic flow meter of insertion type, designed to measure liquid flow from outside a pipe. It is offered in a stainless steel version for hot water.

Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional, for pipes from DN65 to DN6000. Accuracy of ±1.0% of reading above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s, repeatability of 0.2% of reading, resolution of 0.25 mm/s. Response time of 0.5 s, user-selectable display damping from 0 to 99 s. Backlit 4-line by 16-character LCD graphic display, units user-configurable in English and Metric.

Interfaces and connectivity. 4~20 mA outputs (accuracy 0.1%), OCT, relay, RS232, RS485 with Modbus protocol, and data logger function. Temperature measurement by Pt1000 sensor from 0 to 200 °C, accuracy ±0.1%. Thermal energy calculation in GJ or kWh available as an option. Totalization in gallons, ft³, barrels, lbs, liters, m³ and kg.

Power and environment. Power supply AC 85-265 V or DC 24 V / 500 mA. Degree of protection IP66 according to EN60529. Operating temperature from -20 °C to +60 °C, liquid temperature from -35 °C to 85 °C in standard version. Wall-mounted fiberglass housing, dimensions 244 × 196 × 114 mm, weight 2.4 kg. Stainless steel Type S transducers, Φ58 × 199 mm, standard cable length 10 m.

Typical uses and integration. Suited to monitoring hot water and liquid networks, thanks to the RS485 Modbus output that allows connection to a PLC or supervision system. Installation by hot-tapping on a pipe in service, without flow interruption and without pressure drop.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters