DOF6000 – Open Drain Ultrasonic Flow Meter
Open Drain Ultrasonic Flow Meter
- 0°C ~+60°C
- 0°C to 60°C
- 0mm to 10000mm (10m)
- 20mm to 5000mm (5m)
- Manufacturer part number
- DOF6000
- Manufacturer
- Lanry
- Operating Temperature
- 0°C ~+60°C
- Temperature range
- 0°C to 60°C
Lanry super-lowest-price-open-drain-ultrasonic-flow-meter-partially-filled-pipe-open-c, listed under “Ultrasonic Flow Meters”.
- Environmental — Operating Temperature0°C 〜+60°C water temperature
- Operating Temperature0°C ~+60°C
- Temperature range0°C to 60°C
- Depth (Pressure) — Range:0mm to 10000mm (10m)
- Depth (Ultrasonic) — Range:20mm to 5000mm (5m)
- Tilt (Accelerometer) — Range:±70° in roll and pitch axes.
Product overview
Super Lowest Price Open Drain Ultrasonic Flow Meter - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry
Short Description:
Send email to us
Related Video
Feedback (2)
High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for Non Invasive Flow Meter, Mechanical Flow Meter, Mechanical Flow Meter, We have been one of your largest 100% manufacturers in China. A lot of large trading businesses import products and solutions from us, so we can easily give you the most beneficial price tag with the same quality for anyone who is interested in us. Super Lowest Price Open Drain Ultrasonic Flow Meter - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry Detail:
Description
Features
Specificaitons
Installation
Applications
Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.
Water depth is measured with two methods. An ultrasonic depth sensor measures water depth using the ultrasonic principle from a top mounted sensor on the instrument. Depth is also measured using the pressure principle from a bottom mounted sensor in the instrument. These two sensors provide flexibility in depth measurement. Some applications, for example measuring from the side of a pipe, better suits a pressure principle, while other applications in clear open channels better suit an ultrasonic principle.
The QSD6537 Sensor has a 4 electrodes conductivity instrument (EC) included to measure the quality of the water, with four electrodes exposed to the water at the top of the instrument. Water quality is measured on an ongoing basis and this parameter can be recorded along with velocity and depth to better analyse the nature of the water in open channels and pipes.
Features
Velocity Range: 0.02mm/s to 12m/s bi-directional, accuracy is 1%.
Depth Range: 0 to 10m.
Measure velocity in both forward flow and back flow.
Depth is measured by both the pressure sensor and ultrasonic level sensor principles.
With borometric and pressure compensation function.
IP68 Epoxy-sealed body design, designed under water installation.
RS485/MODBUS output, connect to computer directly.
Specificaitons
Sensor:
Caculator:
Installation Details
Partially Filled Pipe
Pipe with Siltation on Bottom
V-notch Shape Channel
Rectangular channel
Pre-formed Two-stage Rectangular Channel
Natrual Stream
Applications
Power Plants
Irrigation & Drainage
River Discharge
Flood Monitoring & Flood Alerts
Rivers and Streams Monitoring
Surface Water Monitoring
Industrial Outflow Monitoring
Wastewater Treatment Plant
Rainwater Measurement
Sewage Treatment
Hydrological Monitoring
Water Supply
Product detail pictures:
Related Product Guide:
We often stay with the principle "Quality Very first, Prestige Supreme". We have been fully committed to supplying our consumers with competitively priced high-quality goods, prompt delivery and skilled provider for Super Lowest Price Open Drain Ultrasonic Flow Meter - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry, The product will supply to all over the world, such as: Portland, Thailand, Canada, Faced with the vitality of the global wave of economic integration, we are confident with our high-quality products and sincerely service to all our customers and wish we can cooperate with you to create a brilliant future.
Flowmeter Open Channel
Four Channels Ultrasonic Flowmeter
Multi Channel Meters
Multi Channel Temperature Meter
Open Channel Flow Measuring Devices
Open Channel Flow Meter Price
Open Channel Flow Meter Wastewater
Pipe Mounted Flow Meter
Ultrasonic Flow Meter Pvc Pipe
Water Pipe Flow Meter
The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers. By Rachel from South Africa - 2018.07.26 16:51
This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap. By Eleanore from Portugal - 2018.07.12 12:19
Highlights
- Case Material: ABS
- Data storage: 16GB
- Depth (Pressure) — Accuracy:: ± 1 % measured
- Depth (Pressure) — Range:: 0mm to 10000mm (10m)
- Depth (Pressure) — Resolution:: 1 mm
- Depth (Ultrasonic) — Accuracy:: ± 1 % measured
Good to know before integrating
- Thermal: rated operating range 0°C 〜+60°C water temperature — check it against the installation environment.
- Thermal: rated operating range 0°C ~+60°C — check it against the installation environment.
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for DOF6000, with where it comes from. Use the filters to find one quickly.
All specifications (37)
| Characteristic | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | ABS |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 1 % measured |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1 % measured |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5″ color LCD |
| Electrical Conductivity (EC) | May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 85-265VAC(Charging battery) |
| Size | 270Lx215Wx175H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Portable |
| Velocity — Velocity accuracy: | ±1 % measured velocity |
| Velocity — Velocity range: | 20mm/sec to 12 m/sec; Bidirectional velocity capability, set using configuration tools |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 3 kg |
No specification matches.
Last verification : 2026-11-03
Technical documentation
Official documents and the technical data recorded for DOF6000. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
Lanry super-lowest-price-open-drain-ultrasonic-flow-meter-partially-filled-pipe-open-c, listed under “Ultrasonic Flow Meters”.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | ABS |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 1 % measured |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1 % measured |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5″ color LCD |
| Electrical Conductivity (EC) | May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 85-265VAC(Charging battery) |
| Size | 270Lx215Wx175H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Portable |
| Velocity — Velocity accuracy: | ±1 % measured velocity |
| Velocity — Velocity range: | 20mm/sec to 12 m/sec; Bidirectional velocity capability, set using configuration tools |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 3 kg |
Integration
Points to check before using DOF6000 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
Power and communication
| Power supply | Calculator: 85-265VAC(Charging battery) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
- Thermal : rated operating range 0°C 〜+60°C water temperature — check it against the installation environment.
- Thermal : rated operating range 0°C ~+60°C — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of DOF6000 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output": Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS.
2Does it support Modbus?
Yes — recorded under "Output": Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS.
3What is the operating temperature range?
0°C 〜+60°C water temperature (source: Environmental — Operating Temperature).
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | DOF6000 |
| Manufacturer | Lanry |