Portable ultrasonic Doppler flow meter from Lanry that simultaneously measures water velocity, depth and conductivity in rivers, open channels and partially filled pipes.
Environmental — Operating Temperature0°C 〜+60°C water temperature
Operating Temperature0°C ~+60°C
Temperature range0°C to 60°C
Depth (Pressure) — Range:0mm to 10000mm (10m)
Depth (Ultrasonic) — Range:20mm to 5000mm (5m)
Tilt (Accelerometer) — Range:±70° in roll and pitch axes.
Product overview
Overview. The Lanry DOF6000-P is a portable ultrasonic Doppler flow meter consisting of a DOF6000 calculator and the Ultraflow QSD 6537 sensor. It measures water velocity, depth and conductivity in rivers, streams, open channels and pipes, and calculates flow rate and total flow when used with the calculator.
Measurement. Velocity is measured in quadrature sampling mode, in both flow directions, over a range of 20 mm/s to 13.2 m/s with an accuracy of ±1 % R. Depth is measured either by pressure sensor (0 to 10 m, accuracy ±2 mm) or by ultrasonic sensor (20 mm to 5 m, accuracy ±1 mm). Electrical conductivity is measured from 0 to 200,000 µS/cm with an accuracy of ±1 % and a resolution of ±1 µS/cm.
Calculation. The calculator determines the cross-sectional area of a partially filled pipe, channel or river from a profile described by up to 20 coordinate points. It includes barometric and pressure compensation.
Connectivity. RS485 output with Modbus RTU protocol (maximum cable 500 m), SDI-12 v1.3 output (maximum cable 50 m), 4-20mA output for flow and depth, pulse output, 16GB data storage and GPRS transmission.
Power and environment. Calculator powered from 85-265 VAC with a rechargeable battery rated for up to 50 hours. The sensor has an IP68 epoxy-sealed body designed for underwater installation, with a marine grade 316 stainless steel mounting bracket. Operating temperature 0 °C to +60 °C, storage temperature -20 °C to +60 °C.
Typical uses. Flow measurement in sewers, channels and streams, including measurement from the side of a pipe. The standard cable is 15 m, extendable to 500 m on request.
Portable ultrasonic Doppler flow meter from Lanry that simultaneously measures water velocity, depth and conductivity in rivers, open channels and partially filled pipes.
Environmental — Operating Temperature0°C 〜+60°C water temperature
Points to check before using DOF6000-P in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0°C 〜+60°C water temperature — check it against the installation environment.
2Thermalrated operating range 0°C ~+60°C — check it against the installation environment.
Power and communication
Power supply
Calculator:85-265VAC (Charging battery)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0°C 〜+60°C water temperature — check it against the installation environment.
Thermal : rated operating range 0°C ~+60°C — check it against the installation environment.
Applications and use cases
Architectures in which DOF6000-P can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hikvision IP and PTZ cameras are managed centrally with HikCentral Professional, Hikvision’s video management software, which Hikvision also supplies preinstalled on its VMS servers
To check
Number of cameras and the HikCentral Professional licences they need
Software only or a VMS server with HikCentral preinstalled, on quotation
Hanwha Vision cameras, recorders and encoders are run with Wisenet WAVE, Hanwha’s video management software for Windows, Ubuntu Linux and macOS, with mobile apps and the WAVE Sync cloud service for remote access
To check
Wisenet WAVE server sizing and licences
Use of the cameras’ onboard analytics in WAVE
Remote access through WAVE Sync
Associated system blocks
CamerasRecording and encodingMounting
Need a complete solution?
Send a request for DOF6000-P and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productLanry
DOF6000-P
Portable ultrasonic Doppler flow meter for channels and pipes
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details