Overview. The Lanry TF1100-DC is a wall-mounted transit-time ultrasonic flow meter with clamp-on transducers fixed to the external pipe wall, for non-invasive measurement of liquid flow in fully filled pipes.
Accuracy and measuring range. Two transducer pairs cover the most common pipe diameters. Accuracy is ±0.5% of reading at rates above 0.3 m/s, and ±0.003 m/s of reading below. Repeatability is 0.15% of reading, resolution 0.1 mm/s. Velocity range 0.01 to 15 m/s, bi-directional. Pipe diameter range: 20-50 mm for type B, 40-4000 mm for type A.
Connectivity and outputs. 4~20 mA outputs (accuracy 0.1%), OCT output, relay, RS485 with Modbus, data logger. Response time 0.5 s, display damping selectable from 0 to 99 s.
Display and use. 4.3-inch colour LCD with 5 lines, 16-key keypad, units user configured in English and Metric. Totalized in gallons, ft³, barrels, lbs, liters, m³ and kg. Keypad and system lockout for security.
Transducers and liquids. Aluminum or stainless steel SUS304 transducers. Clean or somewhat dirty liquids with turbidity below 10000 ppm. Liquid temperature from -35 °C to 200 °C with Pt1000 sensor, 0 to 200 °C, accuracy ±0.1%. Optional thermal energy measurement in GJ or kWh.
Power and environment. Mains supply AC 85-265 V or DC 24 V / 500 mA. Operating temperature -10 °C to +60 °C, minimum operating temperature -30 °C. Degree of protection IP66 according to EN60529. Fiberglass housing, dimensions 244 × 196 × 114 mm, weight 2.4 kg, standard cable length 10 m.
Typical uses. Service and maintenance, replacement of defective meters, control of permanently installed meters, performance measurement of pumps, monitoring of regulating valves, pipeline leak detection.
Integration. The RS485 port with Modbus allows connection to a PLC or a supervision system.