Handheld ultrasonic flowmeter with clamp-on transducers for non-invasive measurement of liquid flow in full pipes, intended for maintenance and control work.
Operating Temperature-20℃ to +60℃
Flow velocity range0.01 to 12 m/s, bi-directional
Response time0.5s
Cable LengthStd: 5m
CommunicationOCT, RS232,Logged data
Damping of displayed value0-99s(selectable by user)
Product overview
Overview. The Lanry TF1100-CH handheld ultrasonic flow meter works on the transit-time method. Clamp-on ultrasonic transducers are mounted on the external surface of the pipe to measure the flow of liquids and liquefied gases in fully filled pipes without intrusion.
Main characteristics. Bi-directional flow velocity range of 0.01 to 12 m/s. Accuracy of ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s. Repeatability of 0.2% of reading, resolution of 0.25 mm/s and response time of 0.5 s. Pipe diameter range of 20 to 50 mm for type S, 40 to 1000 mm for type M and 1000 to 6000 mm for type L.
Interfaces and connectivity. RS-232 output and OCT communication, with logged data function. Backlit 4 line × 16 character graphic LCD display. User-configured units in English and Metric, with totalization in gallons, ft³, barrels, lbs, liters, m³ and kg.
Power and environment. AC supply of 85 to 265 V, and up to 14 hours of operation with fully charged internal batteries. Degree of protection IP65 according to EN60529. Operating temperature of -20 °C to +60 °C, suited liquid temperature of -35 °C to 85 °C, up to 120 °C for short periods. ABS housing (UL 94HB), 212 × 100 × 36 mm, weight 0.5 kg.
Typical uses. Mobile measurement, flow rate calibration, data comparison and checking of permanently installed meters, including temporary replacement of a fixed meter.
Integration. Standard aluminium transducer and PEEK high-temperature transducer suit the pipe. Works in clean and somewhat dirty liquids with turbidity below 10,000 ppm.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for FULL-PIPE-DATA-COMPARING-HANDHELD-PORTABLE-ULTRASONIC-FLOWMETER, with where it comes from. Use the filters to find one quickly.
All specifications (27)
Characteristic
Value
Response time
0.5s
Accuracy
±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s
Cable Length
Std: 5m
Communication
OCT, RS232,Logged data
Damping of displayed value
0-99s(selectable by user)
Degree of protection
IP65 according to EN60529
Display
4 line×16 English letters LCD graphic display, backlit
Enclosure Type
Handheld
Flow velocity range
0.01 to 12 m/s, bi-directional
Housing Material
ABS( UL 94HB)
Liquid Types Supported
both clean and somewhat dirty liquids with turbidity <10000 ppm
Material of transducer
Aluminum for standard temp. s ensor, and peek for high temp. sensor
20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Power supply
AC: 85-265V Up to 14 h with fully charged internal batteries
Rate
Rate and Velocity Display
Repeatability
0.2% of reading
Resolution
0.25mm/s
Security
Keypad lockout, system lockout
Sensitivity
0.003m/s
Size
212*100*36mm
Suited Liquid Temperature
Std. Temp.: -35℃~85℃ for short periods up to 120℃
Totalized
gallons, ft³, barrels, lbs, liters, m³,kg
Transducer Size
Type S 48 (h)*28(w)*2 8 (d)mm
Units
User Configured (English and Metric)
Weight
0.5kg
No specification matches.
Last verification : 2026-11-03
Integration
Points to check before using FULL-PIPE-DATA-COMPARING-HANDHELD-PORTABLE-ULTRASONIC-FLOWMETER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ to +60℃ — check it against the installation environment.
Power and communication
Power supply
AC: 85-265V Up to 14 h with fully charged internal batteries
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ to +60℃ — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of FULL-PIPE-DATA-COMPARING-HANDHELD-PORTABLE-ULTRASONIC-FLOWMETER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-232?
Yes — recorded under "Communication": OCT, RS232,Logged data.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details