DF6100-EP – Portable Doppler ultrasonic flow meter, clamp-on transducers

Portable Doppler ultrasonic flow meter, clamp-on transducers

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • 0.05- 12 m/s
  • 40- 4 000 mm
  • 0.5% -- 2.0% F.S.
Manufacturer part number
PORTABLE-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Flow velocity range
0.05- 12 m/s

Portable Doppler ultrasonic flow meter with clamp-on transducers, designed to measure volumetric flow in closed conduits full of liquid, with flow rate display and totalizer.

Product overview

Overview. The Lanry DF6100-EP portable ultrasonic flow meter is a Doppler flow meter designed to measure volumetric flow in a closed conduit completely filled with liquid. Measurement requires the liquid to contain air bubbles or suspended solids.

Main characteristics. Flow velocity range of 0.05 to 12 m/s, pipe diameters from 40 to 4 000 mm, accuracy of 0.5% to 2.0% of full scale and repeatability of 0.5% of reading. The 2-line × 8-character LCD shows flow rate and totalizer, resettable. Units are user configurable in English or metric.

Interfaces and connectivity. 4-20 mA and OCT outputs. Clamp-on transducers mounted externally, without shutting down the pipe flow during installation.

Power and environment. AC 85-265 V supply, up to 50 hours with fully charged internal batteries. Operating temperature from -20 °C to +60 °C, IP65 protection according to EN60529. Portable ABS housing, transmitter 270 × 125 × 175 mm, 3 kg.

Transducers. Aluminum transducers for standard temperature, PEEK for high temperature, suited liquid temperature from -35 °C to 85 °C for short periods up to 120 °C.

See all specifications

Highlights

  • Response time: 2-60s for optional
  • Accuracy: 0.5% -- 2.0% F.S.
  • Cable Length: Std: 5m
  • Communication: 4-20mA OCT output
  • Degree of protection: IP65 according to EN60529
  • Display: 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable)

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters
Request a quote