QSD6537
RS485 Modbus open channel Doppler ultrasonic flow meter

- Environmental — Operating Temperature
- 0°C 〜+60°C water temperature
- Operating Temperature
- 0°C ~+60°C
- Temperature range
- 0°C to 60°C
- Depth (Pressure) — Range:
- 0mm to 10000mm (10m)
RS485 Modbus open channel Doppler ultrasonic flow meter
Lanry QSD6537 Doppler ultrasonic sensor measuring water velocity, depth and conductivity in rivers, open channels and partially filled pipes, with RS485 Modbus RTU output.
Lanry QSD6537. Doppler ultrasonic open channel flow meter sensor designed to measure water flow velocity, depth and electrical conductivity in rivers, streams, open channels and partially filled pipes.
Measurement principle. Velocity is measured by the ultrasonic Doppler principle in quadrature sampling mode. The instrument transmits ultrasonic energy through its epoxy casing; suspended sediment particles or small gas bubbles reflect part of the signal back to the receiver, which calculates the velocity. The velocity range is 20 mm/s to 12 m/s, bidirectional, with an accuracy of ±1 % of measured velocity.
Depth measurement. Depth is measured by two principles: ultrasonic, from a top-mounted sensor, and pressure, from a bottom-mounted sensor. The range is 20 mm to 5 m for ultrasonic and 0 to 10 m for pressure, with 1 mm resolution and ±1 % of measured value accuracy. The pressure principle suits measurements from the side of a pipe, the ultrasonic principle suits clear open channels.
Conductivity. A four-electrode conductivity sensor, exposed to the water at the top of the instrument, measures from 0 to 200,000 µS/cm, typically ±1 % of measurement. This parameter can be recorded with velocity and depth to analyse water quality.
Main characteristics. Simultaneous measurement of velocity, depth and conductivity, accelerometer tilt sensing (±70° in roll and pitch axes), temperature measured with ±0.5 °C accuracy, 16 GB data storage and a 4.5-inch colour LCD display on the calculator.
Interfaces and connectivity. RS-485 output with Modbus RTU, maximum cable length 500 m, plus pulse output, 4-20 mA output (flow and depth), SDI-12 v1.3 (maximum cable 50 m), datalogger and GPRS.
Power and environment. Calculator powered from 85-265 VAC with a rechargeable battery, sensor rated IP68, operating temperature 0 °C to +60 °C and storage -20 °C to +60 °C. Epoxy-sealed sensor body with Marine Grade 316 stainless steel mounting bracket.
Typical uses and integration. Combined with the Lanry DOF6000 calculator, the set calculates flow rate and total flow, including for a cross section described by up to 20 coordinate points. The RS485 Modbus connection allows integration into a supervision system or PLC. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for QSD6537, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | ABS |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 1 % measured |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1 % measured |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5" color LCD |
| Electrical Conductivity (EC) | May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Next | RS485 modbus area velocity type open channel flow meter doppler ultrasonic flowmeter |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 85-265VAC(Charging battery) |
| Previous | data logger open channel flow meter doppler ultrasonic flowmeter QSD6537 sensor |
| Size | 270Lx215Wx175H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Portable |
| Velocity — Velocity accuracy: | ±1 % measured velocity |
| Velocity — Velocity range: | 20mm/sec to 12 m/sec; Bidirectional velocity capability, set using configuration tools |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 3 kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for QSD6537. For a missing document or a specific revision, our experts send it to you.
Lanry QSD6537 Doppler ultrasonic sensor measuring water velocity, depth and conductivity in rivers, open channels and partially filled pipes, with RS485 Modbus RTU output.
| Parameter | Value |
|---|---|
| Application | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
| Case Material | ABS |
| Data storage | 16GB |
| Depth (Pressure) — Accuracy: | ± 1 % measured |
| Depth (Pressure) — Range: | 0mm to 10000mm (10m) |
| Depth (Pressure) — Resolution: | 1 mm |
| Depth (Ultrasonic) — Accuracy: | ± 1 % measured |
| Depth (Ultrasonic) — Range: | 20mm to 5000mm (5m) |
| Depth (Ultrasonic) — Resolution: | 1 mm |
| Display | 4.5" color LCD |
| Electrical Conductivity (EC) | May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) |
| Electrical Conductivity (EC) — Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Electrical Conductivity (EC) — Resolution | ±1 µS/cm |
| Environmental — IP class: | IP68 |
| Environmental — Operating Temperature | 0°C 〜+60°C water temperature |
| Environmental — Storage Temperature | -20°C 〜+60°C |
| IP Class | Calculator: IP66 |
| Next | RS485 modbus area velocity type open channel flow meter doppler ultrasonic flowmeter |
| Operating Temperature | 0°C ~+60°C |
| Others — Cable: | The standard cable is 15m, the maximum option is 500m. |
| Others — Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
| Others — Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
| Others — Sensor weight: | 1 kg with 15m of cable |
| Output | Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
| Output — RS485 | Modbus RTU, Max. cable 500m |
| Output — SDI-12: | SDI-12 v1.3, Max. cable 50m |
| Power supply | Calculator: 85-265VAC(Charging battery) |
| Previous | data logger open channel flow meter doppler ultrasonic flowmeter QSD6537 sensor |
| Size | 270Lx215Wx175H (mm) |
| Temperature accuracy | ±0.5°C |
| Temperature range | 0°C to 60°C |
| Temperature Resolution | o.1°C |
| Tilt (Accelerometer) — Accuracy: | ±1 ° for angles less than 45° |
| Tilt (Accelerometer) — Range: | ±70° in roll and pitch axes. |
| Type | Portable |
| Velocity — Velocity accuracy: | ±1 % measured velocity |
| Velocity — Velocity range: | 20mm/sec to 12 m/sec; Bidirectional velocity capability, set using configuration tools |
| Velocity — Velocity resolution: | 1 mm/s |
| Weight | 3 kg |
Points to check before using QSD6537 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | Calculator: 85-265VAC(Charging battery) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of QSD6537 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Next": RS485 modbus area velocity type open channel flow meter doppler ultrasonic flowmeter.
Yes — recorded under "Next": RS485 modbus area velocity type open channel flow meter doppler ultrasonic flowmeter.
0°C 〜+60°C water temperature (source: Environmental — Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
RS485 Modbus open channel Doppler ultrasonic flow meter

Area Velocity Flow Meter

Ultrasonic Flow

Agriculture Irrigation Flow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | QSD6537 |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details