SEWER-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER
Portable Doppler clamp-on ultrasonic flow meter for wastewater

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.05- 12 m/s
- Pipe diameter range
- 40- 4 000 mm
- Accuracy
- 0.5% -- 2.0% F.S.
Portable Doppler clamp-on ultrasonic flow meter for wastewater
Portable Doppler ultrasonic flow meter with clamp-on transducers for measuring volumetric flow in a closed conduit full of liquid containing bubbles or suspended solids.
Overview. The Lanry DF6100-EH portable Doppler ultrasonic flow meter measures volumetric flow in a closed conduit completely filled with liquid, provided there are air bubbles or suspended solids in the liquid. It displays flow rate and totalized flow.
Main characteristics. Pipe diameter range of 40 to 4,000 mm, flow velocity range of 0.05 to 12 m/s, accuracy of 0.5% to 2.0% of full scale, repeatability of 0.5% of reading and resolution of 0.25 mm/s. The clamp-on transducers do not require shutting down the pipe during installation. The high-temperature transducer is suitable for liquids from -35 ℃ to 200 ℃.
Display and configuration. 2-line by 8-character LCD, with an 8-digit rate or 8-digit resettable total, 6-button keypad and user-configurable units in English and Metric. Totalization units include gallons, ft³, barrels, lbs, liters, m³ and kg.
Interfaces and connectivity. 4-20 mA and OCT outputs.
Power and environment. AC 85-265 V power supply, up to 14 hours of operation with fully charged internal batteries. Degree of protection IP65 according to EN60529, operating temperature range of -20 ℃ to +60 ℃, minimum operating temperature of -30 °C.
Typical use. Flow measurement of wastewater and effluents in full pipes, such as sewer networks, provided the liquid contains at least 100 ppm of reflectors, at least 20% of which are larger than 100 micron.
Construction. ABS handheld housing, transmitter of 237 × 125 × 42 mm, transducer of 60 × 34 × 32 mm, standard cable of 5 m, weight of 0.6 kg.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SEWER-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 2-60s for optional |
| Accuracy | 0.5% -- 2.0% F.S. |
| Cable Length | Std: 5m |
| Communication | 4-20mA OCT output |
| Degree of protection | IP65 according to EN60529 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Enclosure Type | Handheld |
| Flow velocity range | 0.05- 12 m/s |
| Housing Material | ABS |
| Keypad | 6 pcs buttons |
| Liquid Types Supported | Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Material of transducer | Aluminum for standard temp. sensor,and peek for high temp. sensor |
| Measurement Principle | Doppler ultrasonic |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 40- 4 000 mm |
| Power supply | AC: 85-265V Up to 14 hours with fully charged internal batteries |
| Rate | Rate and Velocity Display |
| Repeatability | 0.5% of reading |
| Resolution | 0.25mm/s |
| Size | Transmitter:237X125X42mm case:410X320X80mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | 60(h)*34(w)*32(d)mm |
| Transducers Type | Clamp-on |
| Units | User Configured (English and Metric) |
| Weight | 0.6kg |
No specification matches.
Last verification : 2026-11-03
Points to check before using SEWER-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V Up to 14 hours with fully charged internal batteries |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SEWER-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER can answer. A question is not asked when nothing is recorded to answer it.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Portable Doppler clamp-on ultrasonic flow meter for wastewater

Clamp On Hand-Hold Doppler Ultrasonic Flowmeter For Activated Sludge

Configured with oct outputs battery power doppler ultrasonic flow meter for drainage

Handheld Doppler Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SEWER-FLOW-METER-HANDHELD-ULTRASONIC-FLOWMETER |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details