TF1100-DI
Insertion dual-channel ultrasonic flow meter

- Operating Temperature
- -10℃ to +60℃
- Flow velocity range
- 0.01 to 15 m/s, bi-directional
- Pipe diameter range
- DN65-5000
- Response time
- 0.5s
Insertion dual-channel ultrasonic flow meter
Insertion-type transit-time ultrasonic flow meter with two channels for measuring liquids in fully filled pipes. Suited to maintenance, control and temporary replacement of installed meters.
Overview. The Lanry TF1100-DI insertion ultrasonic flow meter is a dual-channel transit-time flow meter designed to measure all kinds of liquids in fully filled pipes. Its insertion transducers are hot-tapped without interrupting the flow, need no ultrasonic compound or coupling, and do not intrude into the fluid, so they cause no pressure drop.
Main characteristics. Bi-directional flow velocity range of 0.01 to 15 m/s for pipes from DN65 to DN5000. Accuracy of ±0.5% of reading above 0.3 m/s and ±0.003 m/s below, repeatability of 0.15%, resolution of 0.1 mm/s and response time of 0.5 s. Displayed value damping selectable from 0 to 99 s. Suitable for clean and somewhat dirty liquids with turbidity below 10000 ppm.
Interfaces and connectivity. 4~20 mA output (accuracy 0.1%), OCT output, relay, RS485 port with Modbus protocol and built-in data logger. 4.3-inch colour LCD with 5 lines and 16 keys, units user-configurable in English and Metric. Totalization in gallons, ft³, barrels, lbs, liters, m³ and kg; thermal energy in GJ or kWh optional. Keypad and system lockout security.
Power and environment. Power supply AC 85-265 V or DC 24 V / 500 mA. IP66 degree of protection according to EN60529, wall-mounted fibreglass enclosure. Operating temperature -10 °C to +60 °C, minimum operating temperature -30 °C, liquid temperature range -35 °C to 150 °C. Stainless steel SUS304 and PEEK transducers, PT1000 temperature sensor in insertion or clamp-on version, accuracy ±0.1%. Standard cable length 10 m. Display unit dimensions 244 × 196 × 114 mm, weight 2.4 kg.
Typical uses. Service and maintenance work, replacement of defective meters, performance and efficiency measurement, pump capacity evaluation, monitoring of regulating valves. The Modbus RS485 port allows connection to a PLC or a supervision system.
Integration. Installed by hot-tapping, without interrupting the pipe. For a quotation, contact Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for TF1100-DI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±0.5% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std: 10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4.3’’ color LCD 5 lines display, 16 keys |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 15 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Stainless Steel SUS304+Peek |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Insertion type dual channels ultrasonic flowmeter TF1100-DI |
| Operating Temperature | -10℃ to +60℃ |
| Pipe diameter range | DN65-5000 |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | dual channel ultrasonic clamp-on flow meter with four sensors |
| Rate | Rate and Velocity Display |
| Repeatability | 0.15% of reading |
| Resolution | 0.1mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.001m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | High Temp,:-35℃~150℃ |
| Temperature sensor | PT1000 insertion or clamp-on Accuracy: ±0.1 % |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | φ58*199mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for TF1100-DI. For a missing document or a specific revision, our experts send it to you.
Insertion-type transit-time ultrasonic flow meter with two channels for measuring liquids in fully filled pipes. Suited to maintenance, control and temporary replacement of installed meters.
| Parameter | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±0.5% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std: 10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4.3’’ color LCD 5 lines display, 16 keys |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 15 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Stainless Steel SUS304+Peek |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Next | Insertion type dual channels ultrasonic flowmeter TF1100-DI |
| Operating Temperature | -10℃ to +60℃ |
| Pipe diameter range | DN65-5000 |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | dual channel ultrasonic clamp-on flow meter with four sensors |
| Rate | Rate and Velocity Display |
| Repeatability | 0.15% of reading |
| Resolution | 0.1mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.001m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | High Temp,:-35℃~150℃ |
| Temperature sensor | PT1000 insertion or clamp-on Accuracy: ±0.1 % |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | φ58*199mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
Points to check before using TF1100-DI in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of TF1100-DI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS485 (Modbus),data logger.
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS485 (Modbus),data logger.
-10℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Insertion dual-channel ultrasonic flow meter

Dual-channel insertion ultrasonic flowmeter for metallurgy applications

Data Logger Dual Channel Clamp-On Ultrasonic Flow Meter

Double Channel Clamp On Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | TF1100-DI |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request