TF1100-EC – Wall-mounted bidirectional transit-time ultrasonic flowmeter

Wall-mounted bidirectional transit-time ultrasonic flowmeter

Ultrasonic Flow Meters

  • RS-485
  • Modbus
Manufacturer part number
TF1100-EC
Manufacturer
Lanry

Ultrasonic flowmeter with clamp-on transducers for non-invasive flow measurement of liquids in fully filled pipes, with Modbus RS485 output and data logger function.

Product overview

Overview. The Lanry TF1100-EC wall-mounted transit-time ultrasonic flowmeter measures the flow of liquids and liquefied gases in fully filled pipes using clamp-on transducers, without cutting or interrupting the pipe.

Main characteristics. The flow velocity range is 0.01 to 12 m/s, bidirectional. Accuracy is ±1.0% of reading above 0.3 m/s and ±0.003 m/s of reading below it, with repeatability of 0.2% of reading and a resolution of 0.25 mm/s. Response time is 0.5 s and the damping of the displayed value is adjustable from 0 to 99 s. Liquids with turbidity up to 10,000 ppm are supported.

Display and security. A 3.5-inch colour LCD with 5 display lines and a 16-key keypad allow configuration, with units selectable in English or metric. Keypad lockout and system lockout protect the settings.

Interfaces and communication. The transmitter provides a 4~20 mA output (accuracy 0.1%), an OCT output, a relay, an RS232 interface and an RS485 interface with Modbus protocol. A data logger function is built in. The optional thermal energy measurement, in GJ or kWh, relies on a Pt1000 temperature sensor with ±0.1% accuracy.

Power and environment. The transmitter runs on 85-265 V AC or 24 V DC / 500 mA. Its fibreglass enclosure, rated IP66 according to EN60529, is wall-mounted. It operates between -20 °C and +60 °C, with a minimum operating temperature of -30 °C. The aluminium and PEEK transducers handle liquids from -35 °C to 200 °C, and up to 250 °C for short periods.

Transducer sizing. Type A covers pipes from 40 to 1000 mm, type B pipes from 20 to 50 mm. The transmitter measures 244 × 196 × 114 mm and weighs 2.4 kg.

Typical uses. This flowmeter suits maintenance and temporary replacement of permanently installed meters, pump capacity measurement and monitoring of regulating valves. It applies to water, hot water, cooling water and sea water networks, as well as chemical, petrochemical and food and beverage industries. The Modbus RS485 link allows integration into a PLC or supervisory system.