Transit-time insertion ultrasonic flowmeter with two or four channels for bidirectional flow measurement of clean or slightly dirty liquids in pipes from DN100 to DN2000.

Product overview

Overview. The Lanry TF1100-MI is an insertion ultrasonic flowmeter working on the transit-time difference correlation principle. It is offered in a two-channel or four-channel configuration and is designed for flow measurement in pipes from DN100 to DN2000.

Main characteristics. Accuracy is ±0.5% of reading and repeatability is 0.15% of reading, with a resolution of 0.25 mm/s. The flow velocity range is 0.01 to 12 m/s, bi-directional. The measure cycle is 500 ms. The 9-bit LCD display shows the totalizer, instant flow, error alarm, flow direction, battery level and output.

Interfaces and connectivity. The standard output is RS485 Modbus, complemented by a pulse output. Cellular options are LTE-M / NB-IoT, and NB-IoT/4G/GPRS/GSM depending on the output selected. The transmitter allows connection to a supervision system compatible with Modbus.

Power and environment. Power is supplied by DC3.6V disposable lithium batteries, with a lifetime stated as 10 years or more. The aluminum transmitter is rated IP65 and is wall-mounted. The stainless steel sensors are rated IP68 and suit a process temperature of -35 °C to 85 °C as standard and up to 150 °C in the high temperature version. The operating temperature is -20 °C to +60 °C.

Storage and installation. The device stores forward and backflow data for 10 years, by year, month and day. Installation is by insertion, without interrupting the flow, with a standard 10 m cable.

Typical uses. Bidirectional flow measurement of clean or slightly dirty liquids with turbidity below 10,000 ppm, for remote supervision of distribution networks and pipelines through the cellular outputs and the Modbus link.

Integration. The RS485 Modbus output allows the flowmeter to be connected to PLCs and supervision systems.

System. The TF1100-MI is part of the Lanry ultrasonic flow meter range, which includes the DOF6000-W Series wall-mounted area velocity flowmeter.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters
Request a quote