TF1100-EC – Clamp-on Transit-Time Ultrasonic Flow Meter for Liquids

Clamp-on Transit-Time Ultrasonic Flow Meter for Liquids

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • 0.5s
  • Std:10m
  • Wall-mounted
Manufacturer part number
ULTRASONIC-FLOW-METER-FOR-LIQUID
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Response time
0.5s

Wall-mounted transit-time ultrasonic flow meter with clamp-on transducers fitted to the outside of the pipe, for non-invasive flow measurement of liquids and liquefied gases.

Product overview

Overview. The Lanry TF1100-EC is a wall-mounted transit-time ultrasonic flow meter. Its clamp-on transducers are fitted to the outside of the pipe to measure the flow of liquids and liquefied gases in a fully filled pipe, without cutting the pipe or interrupting the process.

Main characteristics. Bi-directional flow velocity range from 0.01 to 12 m/s. Accuracy of ±1.0 % of reading above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s. Repeatability of 0.2 % of reading. Response time of 0.5 s. Displayed value damping adjustable from 0 to 99 s by the user. Backlit 4-line by 16-character graphic LCD, units configurable in English or metric.

Interfaces and connectivity. 4-20 mA output (accuracy 0.1 %), pulse output (OCT), relay, RS-232, RS-485 with Modbus protocol, and built-in data logger. Clamp-on Pt1000 temperature sensor, accuracy ±0.1 %. Optional thermal energy measurement in GJ or kWh. Totalisation in gallons, ft³, barrels, lbs, liters, m³ and kg.

Power and environment. Power supply AC 85-265 V or DC 24 V / 500 mA. Degree of protection IP66 according to EN60529, fiberglass housing for wall mounting. Operating temperature from -20 °C to +60 °C, suited liquid temperature from -35 °C to 85 °C (up to 120 °C for short periods). Aluminum transducers for standard temperature and PEEK transducers for high temperature.

Typical uses. Suited to clean and somewhat dirty liquids with turbidity below 10,000 ppm. Pipe diameter ranges of 20 to 50 mm (type S), 40 to 1000 mm (type M) and 1000 to 6000 mm (type L). Suitable for service and maintenance, replacement of defective meters and pump performance measurement, in particular in water and wastewater, chemical, food and power generation applications.

Integration. Connection to a PLC or supervision system is possible via RS-485 with Modbus or via the 4-20 mA analogue output.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters
Request a quote