ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE
Transit-time clamp-on ultrasonic flow meter for plastic pipe

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std:10m
Transit-time clamp-on ultrasonic flow meter for plastic pipe
Clamp-on ultrasonic flow meter measuring liquid flow in full pipes without intrusion, with 4-20 mA, RS485 Modbus and data logger outputs.
Overview. The Lanry TF1100-EC is a wall-mounted transit-time ultrasonic flow meter whose clamp-on transducers are fitted to the outside of the pipe to measure the flow of liquids and liquefied gases in fully filled pipes, without cutting the line or interrupting the process.
Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional, with an accuracy of ±1.0% of reading above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s, and a repeatability of 0.2% of reading. Response time of 0.5 s, selectable display damping from 0 to 99 s, resolution of 0.25 mm/s. Backlit 4 line × 16 character graphic LCD. Totalization in gallons, ft³, barrels, lbs, liters, m³ and kg, with user-configured English or metric units. Data logger function and, as an option, thermal energy measurement in GJ or KWh with a Pt1000 temperature sensor of ±0.1% accuracy.
Interfaces and connectivity. 4-20 mA outputs (0.1% accuracy), pulse, relay, RS232, and RS485 with Modbus protocol. Keypad lockout and system lockout for access security.
Power and environment. Power supply of 85-265 V AC or 24 V DC / 500 mA. Degree of protection IP66 according to EN60529. Operating temperature from -20 °C to +60 °C, and liquid temperature from -35 °C to 85 °C for short periods up to 120 °C with the standard transducer. Fiberglass housing measuring 244 × 196 × 114 mm, weight 2.4 kg.
Typical uses. Service and maintenance, replacement of defective meters, control of pumps and regulating valves, performance measurement in water networks, chemical, petrochemical and food and beverage processes, as well as refrigeration and air conditioning systems. The liquid may be clean or somewhat dirty, with turbidity below 10000 ppm.
Integration. Type S (pipes of 20 to 50 mm), M (40 to 1000 mm) and L (1000 to 6000 mm) transducers cover common pipe diameters. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std:10m |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP66 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | Fiberglass |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 244*196*114mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Temperature sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
| Thermal energy | unit GJ,KWh can be optional |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Points to check before using ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
Yes — recorded under "Thermal energy": unit GJ,KWh can be optional.
Yes — recorded under "Communication": 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Transit-time clamp-on ultrasonic flow meter for plastic pipe

Ultrasonic Flow

Agriculture Irrigation Flow Meter

Ultrasonic Clamp On

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details