TF1100-EC – Transit-time clamp-on ultrasonic flow meter for plastic pipe

Transit-time clamp-on ultrasonic flow meter for plastic pipe

Ultrasonic Flow Meters

  • -20℃ to +60℃
  • 0.5s
  • Std:10m
  • Wall-mounted
Manufacturer part number
ULTRASONIC-FLOW-SENSOR-WITH-PLASTIC-PIPE
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Response time
0.5s

Clamp-on ultrasonic flow meter measuring liquid flow in full pipes without intrusion, with 4-20 mA, RS485 Modbus and data logger outputs.

Product overview

Overview. The Lanry TF1100-EC is a wall-mounted transit-time ultrasonic flow meter whose clamp-on transducers are fitted to the outside of the pipe to measure the flow of liquids and liquefied gases in fully filled pipes, without cutting the line or interrupting the process.

Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional, with an accuracy of ±1.0% of reading above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s, and a repeatability of 0.2% of reading. Response time of 0.5 s, selectable display damping from 0 to 99 s, resolution of 0.25 mm/s. Backlit 4 line × 16 character graphic LCD. Totalization in gallons, ft³, barrels, lbs, liters, m³ and kg, with user-configured English or metric units. Data logger function and, as an option, thermal energy measurement in GJ or KWh with a Pt1000 temperature sensor of ±0.1% accuracy.

Interfaces and connectivity. 4-20 mA outputs (0.1% accuracy), pulse, relay, RS232, and RS485 with Modbus protocol. Keypad lockout and system lockout for access security.

Power and environment. Power supply of 85-265 V AC or 24 V DC / 500 mA. Degree of protection IP66 according to EN60529. Operating temperature from -20 °C to +60 °C, and liquid temperature from -35 °C to 85 °C for short periods up to 120 °C with the standard transducer. Fiberglass housing measuring 244 × 196 × 114 mm, weight 2.4 kg.

Typical uses. Service and maintenance, replacement of defective meters, control of pumps and regulating valves, performance measurement in water networks, chemical, petrochemical and food and beverage processes, as well as refrigeration and air conditioning systems. The liquid may be clean or somewhat dirty, with turbidity below 10000 ppm.

Integration. Type S (pipes of 20 to 50 mm), M (40 to 1000 mm) and L (1000 to 6000 mm) transducers cover common pipe diameters. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Ultrasonic Flow Meters
Request a quote