DTSU208
Three-phase DIN rail energy meter with RS485 Modbus-RTU port

- Current
- 1(6)A
- Frequency
- 50Hz/60Hz
- Dimension (HxWxD)
- 99.4mmx72mmx67mm
Three-phase DIN rail energy meter with RS485 Modbus-RTU port
The DTSU208 is a three-phase multifunction DIN rail power sensor that measures energy, voltage, current, power and power factor of electrical grids.
Overview. The Livoltek DTSU208 is a three-phase multifunction energy meter mounted on DIN rail, designed to measure grid parameters including active and reactive energy, voltage, current, power, power factor and frequency.
Main characteristics. The sensor measures total import and export energy in kWh and kvarh, along with instantaneous values of voltage, current, frequency, total and per-phase power factor, and total and per-phase active and reactive power. Instantaneous values refresh every 20 ms. It records 12 months of frozen energy data and 60 days of daily frozen energy data, and supports 4-rate tariffs. The LCD features a backlight.
Interfaces and connectivity. The DTSU208 provides one RS485 port using the Modbus-RTU protocol, with configurable baud rates from 1200 to 115200. An optional external relay output rated 5A 250V AC/30V DC is available.
Power and measurement. The meter operates in three-phase 3P4W or 3P3W connection, with rated voltages up to 3×230/400V and an operating voltage range of 80% to 120% of rated voltage. It is designed for 50 Hz or 60 Hz frequency. Accuracy classes are Class C or 0.5S for active energy and Class 2 for reactive energy. Dimensions: 99.4 mm x 72 mm x 67 mm.
Typical uses. It is used for power data monitoring in distributed photovoltaic installations and energy storage power stations. The RS485 port passes data to inverters and other devices to enable fast response control.
Integration. Its standard DIN rail mounting and compact size make installation in an electrical panel straightforward.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DTSU208, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | Active Accuracy Class: Class C or 0.5S, Reactive Accuracy Class: Class 2 |
| Communication port | RS485 communication port, Modbus-RTU Protocol; Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable) |
| Connection | Three-phase Four-wire (3P4W); Three-phase Three-wire (3P3W) |
| Current | 1(6)A |
| Dimension (HxWxD) | 99.4mmx72mmx67mm |
| Frequency | 50Hz/60Hz |
| Voltage | Rated Voltage: 3×57.7/100V, 3×120/208V, 3×230/400V, 3×240/415V, 3×100V; Operating Voltage Range: 80% to 120% of rated voltage. |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for DTSU208. For a missing document or a specific revision, our experts send it to you.
The DTSU208 is a three-phase multifunction DIN rail power sensor that measures energy, voltage, current, power and power factor of electrical grids.
| Parameter | Value |
|---|---|
| Accuracy | Active Accuracy Class: Class C or 0.5S, Reactive Accuracy Class: Class 2 |
| Communication port | RS485 communication port, Modbus-RTU Protocol; Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable) |
| Connection | Three-phase Four-wire (3P4W); Three-phase Three-wire (3P3W) |
| Current | 1(6)A |
| Dimension (HxWxD) | 99.4mmx72mmx67mm |
| Frequency | 50Hz/60Hz |
| Voltage | Rated Voltage: 3×57.7/100V, 3×120/208V, 3×230/400V, 3×240/415V, 3×100V; Operating Voltage Range: 80% to 120% of rated voltage. |
Answers to the questions that the recorded characteristics of DTSU208 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication port": RS485 communication port, Modbus-RTU Protocol; Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable).
Yes — recorded under "Communication port": RS485 communication port, Modbus-RTU Protocol; Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Three-phase DIN rail energy meter with RS485 Modbus-RTU port

Ethernet TCP Gateway Three Phase Panel Mounted Panel Meter for Electricity Distribution

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DTSU208 |
| Manufacturer | Livoltek |
Energy Meters
Three-phase panel meter with Ethernet TCP gateway
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details